The DOI matches its Crossref record.
Polyamide/silver antimicrobials: Effect of filler types on the silver ion release
Abstract
The efficiency of various silver‐based antimicrobial fillers (elementary silver and silver substituted materials) in polyamide (PA) toward their silver ion (Ag+) release characteristics in an aqueous medium was investigated and discussed. Anode stripping voltammetry (ASV) was used for the quantitative estimation of Ag+ release from these composites. The biocidal (Ag+) release from the composites was found to be dependent on the time of soaking in water and the nature of the filler. The long‐term Ag+ release capability of the elementary silver‐based PA/Ag composite is promising compared with the commercial counterparts. The silver ion release potential of polyamide composites where the silver filling was performed by using supercritical carbon dioxide (scCO 2) is also discussed. The composites release Ag+ at a concentration level capable of rendering antimicrobial efficacy and proved to be active against the microbes. A good agreement exists between the Ag+ release experiments and antimicrobial test results. The observed results on the influence of the nature of the filler and crystallinity on the biocidal release and the varying long‐term release properties could be helpful in the design of industrially relevant biomaterials. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2005
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Duncan, T. V. (2011) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2011.07.017 · Cited by 2,029
Reducing implant-related infections: active release strategies
Hetrick, E. M., & Schoenfisch, M. H. (2006) · Chemical Society Reviews · doi:10.1039/b515219b · Cited by 1,201
Ju-Nam, Y., & Lead, J. R. (2008) · Science of The Total Environment · doi:10.1016/j.scitotenv.2008.06.042 · Cited by 1,037
120 Years of Nanosilver History: Implications for Policy Makers
Nowack, B., Krug, H. F., & Height, M. (2011) · Environmental Science & Technology · doi:10.1021/es103316q · Cited by 829
Monteiro, D. R., Gorup, L. F., Takamiya, A. S., Ruvollo-Filho, A. C., Camargo, E. R. D., & Barbosa, D. B. (2009) · International Journal of Antimicrobial Agents · doi:10.1016/j.ijantimicag.2009.01.017 · Cited by 801
Metadata
- Authors
- Kumar, R., Howdle, S., & Münstedt, H.
- Venue
- Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Publisher
- Wiley
- Published
- 2005-07-06
- Volume
- 75B
- Issue
- 2
- Pages
- 311-319
- ISSN
- 1552-4973 (ISSN-L)
- 1552-4981
- OpenAlex
- W2087543238
- Cited by
- 197
- References
- 0
- FWCI
- 2.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Polyamide/silver antimicrobials: Effect of filler types on the silver ion release. https://app.cochat.ai/papers/10.1002/jbm.b.30306
- The paper
- Kumar, R., Howdle, S., & Münstedt, H. (2005). Polyamide/silver antimicrobials: Effect of filler types on the silver ion release. Journal of Biomedical Materials Research Part B: Applied Biomaterials. https://doi.org/10.1002/jbm.b.30306
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.