CoChat

Repair of the dura mater with processed collagen devices

Zerris, Vasilios A., James, Kenneth S., Roberts, Julie B., Bell, Eugene, Heilman, Carl B. · 2007 · Journal of Biomedical Materials Research Part B: Applied Biomaterials
Cited by 127

The DOI matches its Crossref record.

Abstract

Background: We evaluated in a canine duraplasty model how specific differences in device physicomechanical properties, porosity, and crosslinking influenced the biological performance of three processed collagen dural substitutes. Methods: Three collagen dural substitutes were studied: Dura‐Guard, DuraGen, and Durepair. The initial strength, stiffness, and suture retention force were measured using standard mechanical test methods. The relative pore sizes of each device were assessed with a scanning electron microscope. Differential scanning calorimetry was used to measure their respective collagen denaturation temperatures. The biologic response and performance of the materials were evaluated via an acute (1 month) and long‐term (3 and 6 months) canine bilateral duraplasty study. Results: The mechanical properties of Dura‐Guard and Durepair were similar to native dura. We could not quantify the mechanical properties of DuraGen because of its fragile nature. The denaturation temperature of DuraGen and Dura‐Guard differed significantly from that reported for native collagens. The denaturation temperature of Durepair was comparable with the values reported for native collagens. All three materials were tolerated well by the animals. DuraGen did not maintain its structural integrity beyond 1 month. Dura‐Guard and Durepair persisted for 6 months. Durepair was populated by fibroblasts and blood vessels, whereas Dura‐Guard was not. Conclusions: The three dural substitutes tested were found to be safe and effective in healing surgically created defects in the dura mater. Although each of these dura substitutes are composed of collagen, differences in the collagen source and processing influenced device physicomechanical properties, porosity, and the nativity of the collagen polymer. These measured differences influenced device intraoperative handling and installation as well as the post‐operative biological response, where differences in device resorption, cell penetration, vascularization, and collagen remodeling were observed. © 2007 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2007

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.b.30831

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Zerris, V. A., James, K. S., Roberts, J. B., Bell, E., & Heilman, C. B.
Venue
Journal of Biomedical Materials Research Part B: Applied Biomaterials
Publisher
Wiley
Published
2007-04-26
Volume
83B
Issue
2
Pages
580-588
ISSN
  • 1552-4973 (ISSN-L)
  • 1552-4981
OpenAlex
W2050014023
Cited by
127
References
0
FWCI
1.93
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.