The DOI matches its Crossref record.
In vivo response of porous hydroxyapatite and β‐tricalcium phosphate prepared by aqueous solution combustion method and comparison with bioglass scaffolds
Abstract
Pure hydroxyapatite (HAp) and a biphasic calcium phosphate [containing 90% of β‐tri‐calcium phosphate (β‐TCP) and 10% HAp] were tailored through an aqueous solution combustion synthesis. Porous struts were prepared using all the powders along with bioglass, a known bioactive material, and subsequently characterized. Sterilized struts were implanted to the lateral side of radius bone of 24 black Bengal goats of either sex, in which a blank hole was left unfilled in a group of six specimens to act as control. The bone formation response of the three implanting materials in vivo has been studied using scanning electron microscope and histological analysis in contrast with positive controls. Push‐out tests were used to assess the mechanical strength at the bone–biomaterial interface. It was observed that interfacial response was strongly dependent on combinations of different physical and chemical parameters. The surface of β‐TCP exhibited similar characteristics of bone and was distinct from those of intervening apatite layer of bioglass. Lower bone ingrowth and reduced strength was observed with HAp compared to β‐TCP/bioglass‐based implants. Bone formation response of the Ca‐P material varied according to the composition of the implanting material, which could be tailored through this novel synthesis. © 2007 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2008
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Normal Bone Anatomy and Physiology
Clarke, B. (2008) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.04151206 · Cited by 2,192
Solution Combustion Synthesis of Nanoscale Materials
Varma, A., Mukasyan, A. S., Rogachev, A. S., & Manukyan, K. V. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00279 · Cited by 1,453
Bioactive Glass and Glass-Ceramic Scaffolds for Bone Tissue Engineering
Gerhardt, L.-C., & Boccaccini, A. R. (2010) · Materials · doi:10.3390/ma3073867 · Cited by 1,179
Fernandez de Grado, G., Keller, L., Idoux-Gillet, Y., Wagner, Q., Musset, A.-M., Benkirane-Jessel, N., Bornert, F., & Offner, D. (2018) · Journal of Tissue Engineering · doi:10.1177/2041731418776819 · Cited by 912
Samavedi, S., Whittington, A. R., & Goldstein, A. S. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.06.014 · Cited by 802
Metadata
- Authors
- Ghosh, S. K., Nandi, S. K., Kundu, B., Datta, S., De, D. K., Roy, S. K., & Basu, D.
- Venue
- Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Publisher
- Wiley
- Published
- 2007-12-27
- Volume
- 86B
- Issue
- 1
- Pages
- 217-227
- ISSN
- 1552-4973 (ISSN-L)
- 1552-4981
- OpenAlex
- W2130957037
- Cited by
- 170
- References
- 0
- FWCI
- 4.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In vivo response of porous hydroxyapatite and β‐tricalcium phosphate prepared by aqueous solution combustion method and comparison with bioglass scaffolds. https://app.cochat.ai/papers/10.1002/jbm.b.31009
- The paper
- Ghosh, S. K., Nandi, S. K., Kundu, B., Datta, S., De, D. K., Roy, S. K., & Basu, D. (2008). In vivo response of porous hydroxyapatite and β‐tricalcium phosphate prepared by aqueous solution combustion method and comparison with bioglass scaffolds. Journal of Biomedical Materials Research Part B: Applied Biomaterials. https://doi.org/10.1002/jbm.b.31009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.