Swelling characteristics and drug delivery properties of nifedipine‐loaded pH sensitive alginate–chitosan hydrogel beads
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The aim of the present work was to investigate the swelling behavior and in vitro release of nifedipine from alginate–chitosan hydrogel beads. Structure and surface morphology of the hydrogel were characterized by FTIR and SEM, respectively. Alginate–chitosan mixed beads and alginate–chitosan coated beads were prepared by ionic gelation method. The swelling ability of the beads and in vitro release of nifedipine in simulated gastric fluid (pH 1.5) and different phosphate buffer solutions (pH 2.5, 5.0, 6.8, 7.4, and 8.0) were found to be dependent on the presence of the polyelectrolyte complex between chitosan and alginate. The amount of nifedipine released from the mixed beads at pH 1.5 was relatively low (42%), whereas this value approached to 99% at pH 6.8. In comparison with the mixed beads, the released nifedipine from the coated beads was minimal at pH 1.5 (18%), whereas ∼99% nifedipine was released at pH 6.8. The results suggested that the coated beads can hold drug better at low pH than the mixed beads and show excellent pH sensitivity. Therefore, the alginate–chitosan coated beads could be a suitable polymeric carrier for drug delivery in the intestinal tract. © 2008 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2008
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hydrogels for biomedical applications
Hoffman, A. S. (2002) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(01)00239-3 · Cited by 4,864
Cited by
A review on chitosan and its nanocomposites in drug delivery
Ali, A., & Ahmed, S. (2018) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2017.12.078 · Cited by 1,127
A comprehensive review on polyelectrolyte complexes
Meka, V. S., Sing, M. K. G., Pichika, M. R., Nali, S. R., Kolapalli, V. R. M., & Kesharwani, P. (2017) · Drug Discovery Today · doi:10.1016/j.drudis.2017.06.008 · Cited by 489
Unagolla, J. M., & Jayasuriya, A. C. (2018) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2017.12.012 · Cited by 414
Chitosan-Alginate Nanoparticles as a Novel Drug Delivery System for Nifedipine
The Second Hospital of Lanzhou University, L., Li, P., Dai, Y.-N., Pharmacy College of Lanzhou University, L., Zhang, J.-P., Lanzhou Institute of Chemical Physics, C. A. O. S., Wei, Q., & The Second Hospital of Lanzhou University, L. (2008) · International Journal of Biomedical Science · doi:10.59566/ijbs.2008.4221 · Cited by 386
Self-citationKhan, A., Pan, X., Najeeb, U., Tan, D. K. Y., Fahad, S., Zahoor, R., & Luo, H. (2018) · Biological Research · doi:10.1186/s40659-018-0198-z · Cited by 261
Metadata
- Authors
- Dai, Y., Li, P., Zhang, J., Wang, A., & Wei, Q.
- Venue
- Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Publisher
- Wiley
- Published
- 2008-03-21
- Volume
- 86B
- Issue
- 2
- Pages
- 493-500
- ISSN
- 1552-4973 (ISSN-L)
- 1552-4981
- OpenAlex
- W2007264379
- Cited by
- 139
- References
- 1
- FWCI
- 5.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.