The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
In vitro/in vivo biocompatibility and mechanical properties of bioactive glass nanofiber and poly(ε‐caprolactone) composite materials
Abstract
In this study, a poly(ε‐caprolactone) (PCL)/bioactive glass (BG) nanocomposite was fabricated using BG nanofibers (BGNFs) and compared with an established composite fabricated using microscale BG particles. The BGNFs were generated using sol–gel precursors via the electrospinning process, chopped into short fibers and then incorporated into the PCL organic matrix by dissolving them in a tetrahydrofuran solvent. The biological and mechanical properties of the PCL/BGNF composites were evaluated and compared with those of PCL/BG powder (BGP). Because the PCL/BG composite containing 20 wt % BG showed the highest level of alkaline phosphatase (ALP) activity, all evaluations were performed at this concentration except for that of the ALP activity itself. In vitro cell tests using the MC3T3 cell line demonstrated the enhanced biocompatibility of the PCL/BGNF composite compared with the PCL/BGP composite. Furthermore, the PCL/BGNF composite showed a significantly higher level of bioactivity compared with the PCL/BGP composite. In addition, the results of the in vivo animal experiments using Sprague–Dawley albino rats revealed the good bone regeneration capability of the PCL/BGNF composite when implanted in a calvarial bone defect. In the result of the tensile test, the stiffness of the PCL/BG composite was further increased when the BGNFs were incorporated. These results indicate that the PCL/BGNF composite has greater bioactivity and mechanical stability when compared with the PCL/BG composite and great potential as a bone regenerative material. © 2009 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2009
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biodegradable synthetic polymers for tissue engineering
CSIRO Molecular Science, B. 1., & Gunatillake, P. (2003) · European Cells and Materials · doi:10.22203/ecm.v005a01 · Cited by 1,765 · cited 1×
“Biodegradable synthetic polymers, such as poly(glycolic acid), poly(lactic acid), poly(e-caprolactone) (PCL), and their copolymers, have been widely used as the matrices in these composites, because they have favorable biocompatibility and degradability.(4) Among these polymers, PCL is a common biodegradable, FDA-appr…”
Background
Cited by
Design, fabrication and characterization of PCL electrospun scaffolds—a review
Cipitria, A., Skelton, A., Dargaville, T. R., Dalton, P. D., & Hutmacher, D. W. (2011) · Journal of Materials Chemistry · doi:10.1039/c0jm04502k · Cited by 627
Polymer/bioactive glass nanocomposites for biomedical applications: A review
Boccaccini, A. R., Erol, M., Stark, W. J., Mohn, D., Hong, Z., & Mano, J. F. (2010) · Composites Science and Technology · doi:10.1016/j.compscitech.2010.06.002 · Cited by 520
Zhao, S., Li, L., Wang, H., Zhang, Y., Cheng, X., Zhou, N., Rahaman, M. N., Liu, Z., Huang, W., & Zhang, C. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.02.112 · Cited by 394
Electrospun fibers for tissue engineering, drug delivery, and wound dressing
Goh, Y.-F., Shakir, I., & Hussain, R. (2013) · Journal of Materials Science · doi:10.1007/s10853-013-7145-8 · Cited by 318
Current Progress in Bioactive Ceramic Scaffolds for Bone Repair and Regeneration
Gao, C., Deng, Y., Feng, P., Mao, Z., Li, P., Yang, B., Deng, J., Cao, Y., Shuai, C., & Peng, S. (2014) · International Journal of Molecular Sciences · doi:10.3390/ijms15034714 · Cited by 310
Metadata
- Authors
- Jo, J., Lee, E., Shin, D., Kim, H., Kim, H., Koh, Y., & Jang, J.
- Venue
- Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Publisher
- Wiley
- Published
- 2009-05-06
- Volume
- 91B
- Issue
- 1
- Pages
- 213-220
- ISSN
- 1552-4973 (ISSN-L)
- 1552-4981
- OpenAlex
- W2031964302
- Cited by
- 163
- References
- 1
- FWCI
- 5.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.