The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Meta-analysis of vertebral augmentation compared with conservative treatment for osteoporotic spinal fractures
Abstract
Cement augmentation is a controversial treatment for painful vertebral compression fractures (VCF). Our research questions for the meta-analysis were: Is there a clinical and statistical difference in pain relief, functional improvement, and quality of life between conservative care and cement augmentation for VCF and, if so, are they maintained at longer time points? We conducted a search of MEDLINE from January 1980 to July 2011 using PubMed, Cochrane Database of Systematic Reviews and Controlled Trials, CINAHL, and EMBASE. Searches were performed from Medical Subject Headings. Terms “vertebroplasty” and “compression fracture” were used. The outcome variables of pain, functional measures, health-related quality of life (HRQOL), and new fracture risk were analyzed. A random effects model was chosen. Continuous variables were calculated using the standardized mean difference comparing improvement from baseline of the experimental group with the control group. New vertebral fracture risk was calculated using log odds ratio. Six studies met the criteria. The pain visual analog scale (VAS) mean difference was 0.73 (confidence interval [CI] 0.35, 1.10) for early (<12 weeks) and 0.58 (CI 0.19, 0.97) for late time points (6 to 12 months), favoring vertebroplasty (p < 0.001). The functional outcomes at early and late time points were statistically significant with 1.08 (CI 0.33, 1.82) and 1.16 (CI 0.14, 2.18), respectively. The HRQOL showed superior results of vertebroplasty compared with conservative care at early and late time points of 0.39 (CI 0.16, 0.62) and 0.33 (CI 0.16, 0.51), respectively. Secondary fractures were not statistically different between the groups, 0.065 (CI −0.57, 0.70). This meta-analysis showed greater pain relief, functional recovery, and health-related quality of life with cement augmentation compared with controls. Cement augmentation results were significant in the early (<12 weeks) and the late time points (6 to 12 months). This meta-analysis provides strong evidence in favor of cement augmentation in the treatment of symptomatic VCF fractures. © 2013 American Society for Bone and Mineral Research
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Farrar, J. T., Young, J. P., LaMoreaux, L., Werth, J. L., & Poole, M. R. (2001) · Pain · doi:10.1016/s0304-3959(01)00349-9 · Cited by 5,808
Cited by
Percutaneous vertebroplasty for osteoporotic vertebral compression fracture
Buchbinder, R., Golmohammadi, K., Johnston, R. V., Owen, R. J., Homik, J., Jones, A., Dhillon, S. S., Kallmes, D. F., & Lambert, R. G. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006349.pub2 · Cited by 279
Metadata
- Authors
- Anderson, P. A., Froyshteter, A. B., & Tontz, W. L.
- Venue
- Journal of Bone and Mineral Research
- Publisher
- Oxford University Press (OUP)
- Published
- 2012-09-18
- Volume
- 28
- Issue
- 2
- Pages
- 372-382
- ISSN
- 0884-0431 (ISSN-L)
- 1523-4681
- OpenAlex
- W2082418053
- Cited by
- 203
- References
- 1
- FWCI
- 2.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.