The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Site-matched calcaneal measurements of broad-band ultrasound attenuation and single X-ray absorptiometry: Do they measure different skeletal properties?
Abstract
Because of the differences in the interactions of ultrasound and x-ray waves with bone, quantitative ultrasound (QUS) techniques may yield information about skeletal status not accessible by regular bone densitometry (BD) techniques. However, relatively strong correlations have been reported between broad-band ultrasound attenuation (BUA) and several x-ray-based BD methods. We assessed the precision and association of single x-ray absorptiometry (SXA) and BUA of the calcaneus. We examined both BUA and SXA at the calcaneus using special software for matching the regions of interest. An algorithm was derived and applied to correct the observed correlation coefficients for the attenuation effect caused by the precision errors for BUA and SXA. In a group of 33 volunteers covering a wide range of age and calcaneal bone mineral densities, the site-matched and precision-adjusted correlation coefficient between BUA and SXA was r = 0.58, with a standard error of the estimate (SEE) of 14.41 dB/MHz, or 17.08%. For the subgroup of 25 women the correlation was stronger, with r = 0.72 and SEE = 11.53 dB/MHz, or 14.33%. SXA precision was 0.79% for the regular region of interest (ROI) and 1.22% for the site-matched ROI. BUA precision was 2.76% for the entire subject group and 1.63% for women of age 40 or older. The observed correlation coefficient between ultrasound and x-ray based techniques of the order of 0.7 is significant, but it leaves about 50% of the variability unexplained. It remains to be investigated to what extent the unexplained 50% is related to bone strength or structure or whether it reflects a variability unrelated to osteoporosis status.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mosekilde, L. (1989) · Bone · doi:10.1016/8756-3282(89)90074-4 · Cited by 316
Cited by
Glüer, C. C., Blake, G., Lu, Y., Blunt1, B. A., Jergas1, M., & Genant1, H. K. (1995) · Osteoporosis International · doi:10.1007/bf01774016 · Cited by 1,282
Self-citationNoninvasive assessment of bone mineral and structure: State of the art
Genant, H. K., Engelke, K., Fuerst, T., Glüer, C.-C., Grampp, S., Harris, S. T., Jergas, M., Lang, T., Lu, Y., Majumdar, S., et al. (1996) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650110602 · Cited by 941
Self-citationClinical Use of Bone Densitometry: Scientific Review
Cummings, S. R., Bates, D., & Black, D. M. (2002) · JAMA · doi:10.1001/jama.288.15.1889 · Cited by 817
Self-citationBauer, D. C. (1997) · Archives of Internal Medicine · doi:10.1001/archinte.1997.00440270067006 · Cited by 800
The role of ultrasound in the assessment of osteoporosis: A review
Njeh, C. F., Boivin, C. M., & Langton, C. M. (1997) · Osteoporosis International · doi:10.1007/bf01623454 · Cited by 540
Metadata
- Authors
- Glüer, C. C., Vahlensieck, M., Faulkner, K. G., Engelke, K., Black, D., & Genant, H. K.
- Venue
- Journal of Bone and Mineral Research
- Publisher
- Oxford University Press (OUP)
- Published
- 1992-09-01
- Volume
- 7
- Issue
- 9
- Pages
- 1071-1079
- ISSN
- 0884-0431 (ISSN-L)
- 1523-4681
- OpenAlex
- W2030858225
- Cited by
- 162
- References
- 1
- FWCI
- 16.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Site-matched calcaneal measurements of broad-band ultrasound attenuation and single X-ray absorptiometry: Do they measure different skeletal properties? https://app.cochat.ai/papers/10.1002/jbmr.5650070910
- The paper
- Glüer, C. C., Vahlensieck, M., Faulkner, K. G., Engelke, K., Black, D., & Genant, H. K. (1992). Site-matched calcaneal measurements of broad-band ultrasound attenuation and single X-ray absorptiometry: Do they measure different skeletal properties? Journal of Bone and Mineral Research. https://doi.org/10.1002/jbmr.5650070910
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.