The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Geometric structure of the femoral neck measured using dual-energy X-ray absorptiometry
Abstract
An algorithm was developed to estimate the strength of the femoral neck from data generated by the dual-energy x-ray absorptiometry (DXA). This algorithm considers shape of the proximal femur as well as cross-sectional moment of inertia (CSMI) in the estimate. Proximal femora (10) from cadavers of white adults and an aluminum step wedge were scanned with the Lunar DPX to validate the calculation of CSMI. After scanning, each femoral neck was sectioned at its narrowest portion for direct measurement of CSMI. Three healthy young women were scanned five times each to evaluate the reproducibility of geometric measurements using DXA. There was a strong linear association between the CSMI measured directly and using DXA in both cadaver bones (r2 = 0.96) and the aluminum step wedge (r2 = 0.99). The coefficient of variation for CSMI from repeated measurements using DXA was less than 3%. This indicates that it is possible to estimate reproducibly the bending rigidity of bone from DXA measurements. The data from 306 normal subjects were analyzed to investigate geometric changes in the femoral neck with age. Although there was no strong correlation between CSMI and age in normal subjects of either sex, safety factor (SF, an index of strength of the femoral neck during walking) and fall index (FI, an index of the strength of the femoral neck during a fall) decrease with age in both sexes. We observed an alteration of the geometric structure of the femoral neck with age that may increase the stress on the femoral neck and decrease SF and FI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pre-Existing Fractures and Bone Mass Predict Vertebral Fracture Incidence in Women
Ross, P. D., Davis, J. W., Epstein, R. S., & Wasnich, R. D. (1991) · Annals of Internal Medicine · doi:10.7326/0003-4819-114-11-919 · Cited by 1,107
Aging of bone tissue: mechanical properties
Burstein, A., Reilly, D., & Martens, M. (1976) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197658010-00015 · Cited by 569
Cited by
Relation between age, femoral neck cortical stability, and hip fracture risk
Mayhew, P. M., Thomas, C. D., Clement, J. G., Loveridge, N., Beck, T. J., Bonfield, W., Burgoyne, C. J., & Reeve, J. (2005) · The Lancet · doi:10.1016/s0140-6736(05)66870-5 · Cited by 397
Males Have Larger Skeletal Size and Bone Mass Than Females, Despite Comparable Body Size
Nieves, J. W., Formica, C., Ruffing, J., Zion, M., Garrett, P., Lindsay, R., & Cosman, F. (2005) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.041005 · Cited by 358
Kaptoge, S., Beck, T. J., Reeve, J., Stone, K. L., Hillier, T. A., Cauley, J. A., & Cummings, S. R. (2008) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.080802 · Cited by 283
Lang, T. F., Keyak, J. H., Heitz, M. W., Augat, P., Lu, Y., Mathur, A., & Genant, H. K. (1997) · Bone · doi:10.1016/s8756-3282(97)00072-0 · Cited by 270
Duan, Y., Beck, T. J., Wang, X.-F., & Seeman, E. (2003) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2003.18.10.1766 · Cited by 253
Metadata
- Authors
- Yoshikawa, T., Turner, C. H., Peacock, M., Slemenda, C. W., Weaver, C. M., Teegarden, D., Markwardt, P., & Burr, D. B.
- Venue
- Journal of Bone and Mineral Research
- Publisher
- Oxford University Press (OUP)
- Published
- 1994-07-01
- Volume
- 9
- Issue
- 7
- Pages
- 1053-1064
- ISSN
- 0884-0431 (ISSN-L)
- 1523-4681
- OpenAlex
- W2151221479
- Cited by
- 238
- References
- 2
- FWCI
- 5.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Geometric structure of the femoral neck measured using dual-energy X-ray absorptiometry. https://app.cochat.ai/papers/10.1002/jbmr.5650090713
- The paper
- Yoshikawa, T., Turner, C. H., Peacock, M., Slemenda, C. W., Weaver, C. M., Teegarden, D., Markwardt, P., & Burr, D. B. (1994). Geometric structure of the femoral neck measured using dual-energy X-ray absorptiometry. Journal of Bone and Mineral Research. https://doi.org/10.1002/jbmr.5650090713
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.