Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 238

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Geometric structure of the femoral neck measured using dual-energy X-ray absorptiometry

Yoshikawa, T., Turner, C.H., Peacock, M., Slemenda, C.W., Weaver, C.M., Teegarden, D., Markwardt, P., Burr, D.B.·1994·Journal of Bone and Mineral Research

Abstract

An algorithm was developed to estimate the strength of the femoral neck from data generated by the dual-energy x-ray absorptiometry (DXA). This algorithm considers shape of the proximal femur as well as cross-sectional moment of inertia (CSMI) in the estimate. Proximal femora (10) from cadavers of white adults and an aluminum step wedge were scanned with the Lunar DPX to validate the calculation of CSMI. After scanning, each femoral neck was sectioned at its narrowest portion for direct measurement of CSMI. Three healthy young women were scanned five times each to evaluate the reproducibility of geometric measurements using DXA. There was a strong linear association between the CSMI measured directly and using DXA in both cadaver bones (r2 = 0.96) and the aluminum step wedge (r2 = 0.99). The coefficient of variation for CSMI from repeated measurements using DXA was less than 3%. This indicates that it is possible to estimate reproducibly the bending rigidity of bone from DXA measurements. The data from 306 normal subjects were analyzed to investigate geometric changes in the femoral neck with age. Although there was no strong correlation between CSMI and age in normal subjects of either sex, safety factor (SF, an index of strength of the femoral neck during walking) and fall index (FI, an index of the strength of the femoral neck during a fall) decrease with age in both sexes. We observed an alteration of the geometric structure of the femoral neck with age that may increase the stress on the femoral neck and decrease SF and FI.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbmr.5650090713

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 238

Metadata

Authors
Yoshikawa, T., Turner, C. H., Peacock, M., Slemenda, C. W., Weaver, C. M., Teegarden, D., Markwardt, P., & Burr, D. B.
Venue
Journal of Bone and Mineral Research
Published
1994-07-01
Volume
9
Issue
7
Pages
1053-1064
ISSN
  • 0884-0431 (ISSN-L)
  • 1523-4681
OpenAlex
W2151221479
Cited by
238
References
2
FWCI
5.09
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Geometric structure of the femoral neck measured using dual-energy X-ray absorptiometry. https://app.cochat.ai/papers/10.1002/jbmr.5650090713
The paper
Yoshikawa, T., Turner, C. H., Peacock, M., Slemenda, C. W., Weaver, C. M., Teegarden, D., Markwardt, P., & Burr, D. B. (1994). Geometric structure of the femoral neck measured using dual-energy X-ray absorptiometry. Journal of Bone and Mineral Research. https://doi.org/10.1002/jbmr.5650090713

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.