The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Adverse reactions associated with mobile therapeutic apheresis: analysis of 17,940 procedures.
Abstract
In order to evaluate the nature and frequency of adverse reactions associated with Therapeutic Apheresis (TA), database information from two large mobile apheresis services was analyzed. A total of 17,940 procedures performed on 3,583 patients were studied using an Access Database. Seventy percent (12,558) of the procedures were performed on a Fresenius AS104 blood cell separator and 30% (5,382) were performed on a COBE Spectra. The five most commonly treated diseases were Guillain‐Barre Syndrome (25%), thrombotic thrombocytopenic purpura (20%), myasthenia gravis (18%), the hyperviscosity syndrome (12%), and chronic inflammatory demyelinating polyneuropathy (9%). All patients received calcium gluconate supplement during the procedures. Cardiac monitoring was used during 80% of the procedures and blood pressure monitoring was used during all procedures. All procedures were supervised by a physician. Both apheresis services fully comply with the ASFA Guidelines for Therapeutic Apheresis Providers. Adverse reactions occurred in 3.9% of all procedures. The following adverse reactions were documented: reactions related to ACD toxicity (3%), vasovagal reactions (0.5%), vascular access related complications (0.15%), reactions related to FFP (0.12%), hepatitis B from FFP (0.06%), arrhythmias (0.01%), hemolysis due to inappropriate dilution of 25% albumin (0.01%), and one death (from underlying disease) during a TA procedure (0.006%). These data demonstrate that therapeutic apheresis is associated with a low rate of side effects when performed by well‐trained and certified nurses under the direction of experienced physicians, even in the diverse setting of large mobile therapeutic apheresis programs. J Clin Apheresis 16:130–133, 2001. © 2001 Wiley‐Liss, Inc.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
There is a procedure for human patients analogous to NBE, called Therapeutic Plasma Exchange (TPE), which is FDA approved and routinely used in the clinic.
“there is a procedure for human patients analogous to NBE, where most of the plasma is replaced by physiologic solution supplemented with commercial human albumin, called Therapeutic Plasma Exchange, TPE, which is FDA approved and routinely used in the clinic [16–18].”
From Rejuvenation of three germ layers tissues by exchanging old blood plasma with saline-albumin (2020) · cites this paper as [17]
Human blood samples were provided under an IRB approved by Sutter Health, without personal identifiers, and were not linked to or traced back to personal information.
“On shelf samples of human blood (collected through the FDA approved and routinely used in the clinic procedure of Therapeutic Plasma Exchange [16–18]) were provided to us by Dr. Dobri Kiprov (IRB Approved by Sutter health, 648823) without personal identifiers and were not linked to or traced back to any personal information in our study.”
From Rejuvenation of three germ layers tissues by exchanging old blood plasma with saline-albumin (2020) · cites this paper as [17]
Citations
Cites
Frequency of immediate adverse effects associated with apheresis donation
McLeod, B. C., Price, T. H., Owen, H., Ciavarella, D., Sniecinski, I., Randels, M. J., & Smith, J. W. (1998) · Transfusion · doi:10.1046/j.1537-2995.1998.381098440858.x · Cited by 136
Flagged first, then by citations
Research works printed but not linked: 12
- 10.7326/0003-4819-131-6-199909210-00011 · DOI
- 10.1002/(SICI)1098-1101(2000)15:1/2<1::AID-JCA1>3.0.CO;2-R · DOI
- 10.1046/j.1537-2995.1989.29289146829.x · DOI
- 10.1046/j.1537-2995.1986.26286152904.x · DOI
- Puig L, 1985, Adverse effects secondary to the treatment with plasma exchange, Int J Artif Organs, 8, 156, 10.1177/039139888500800309 · DOI
- 10.1111/j.1423-0410.1984.tb00086.x · DOI
- 10.1016/0955-3886(95)00039-9 · DOI
- 10.1002/jca.2920090102 · DOI
- McLeod BC, 1996, Organizational Guidelines for Therapeutic Apheresis Facilities. A document prepared by ASFA Standards and Education Committee, J Clin Apheresis, 11, 42
- 10.1046/j.1537-2995.1999.39399219285.x · DOI
- Huestis DW, 1989, Risks and safety practices in hemapheresis procedures, Arch Pathol Lab Med, 113, 273
- 10.1001/archneur.1982.00510180028007 · DOI
Cited by
Sorted by citations
Rejuvenation of three germ layers tissues by exchanging old blood plasma with saline-albumin
Mehdipour, M., Skinner, C., Wong, N., Lieb, M., Liu, C., Etienne, J., Kato, C., Kiprov, D., Conboy, M. J., & Conboy, I. M. (2020) · Aging · doi:10.18632/aging.103418 · Cited by 115
Self-citation
Metadata
- Authors
- Kiprov, D. D., Golden, P., Rohe, R., Smith, S., Hofmann, J., & Hunnicutt, J.
- Venue
- Journal of Clinical Apheresis
- Publisher
- Wiley
- Published
- 2001-01
- Volume
- 16
- Issue
- 3
- Pages
- 130-133
- ISSN
- 0733-2459
- 1098-1101
- Cited by
- 46
- References
- 1
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review