Differential Diagnostics of Thalassemia Minor by Artificial Neural Networks Model: New Screening Tool for Thalassemia Minor
Open accessThe DOI matches its Crossref record.
Abstract
BACKGROUND: Current methods used to diagnose the thalassemia minor (TM) patients require high-cost assays, while broader screening based on routine blood count has limited specificity and sensitivity. This study developed a new screening technique for TM patients' diagnosis. METHODS: The study enrolled 526 patients database that included 185 verified α and β TM cases, and control group consisted of iron-deficiency anemia (IDA), myelodysplastic syndrome (MDS), and healthy patients. More than 1,500 artificial neural networks (ANNs) models were created and the networks that gave high accuracy were selected for the study. TM patients were identified from the general database using the best-optimized ANNs. RESULTS: Comparison between three or six routine blood count parameters determined a slightly higher accuracy of the model with the three-parameter scheme, including mean corpuscular volume, red blood cell distribution width, and red blood cell. Based on these parameters, we were able to separate TM patients from the control group and MDS group, with specificity of 0.967 and sensitivity of 1. Including IDA patients into comparison gave lower but, still, very good values of specificity of 0.968 and sensitivity of 0.9. CONCLUSION: ANN-based TM diagnostics should be used for broad automatic screening of general population prior diagnosis with high-cost tests.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Machine learning-based clinical decision support using laboratory data
Çubukçu, H. C., Topcu, D. İ., & Yenice, S. (2024) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2023-1037 · Cited by 66
Urrechaga, E., & Hoffmann, J. J. M. L. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2016-0856 · Cited by 47
Purwar, S., Tripathi, R. K., Ranjan, R., & Saxena, R. (2020) · Multimedia Tools and Applications · doi:10.1007/s11042-019-07927-0 · Cited by 46
Machine Learning-Based Prediction of Hemoglobinopathies Using Complete Blood Count Data
Schipper, A., Rutten, M., van Gammeren, A., Harteveld, C. L., Urrechaga, E., Weerkamp, F., den Besten, G., Krabbe, J., Slomp, J., Schoonen, L., et al. (2024) · Clinical Chemistry · doi:10.1093/clinchem/hvae081 · Cited by 33
Metadata
- Authors
- Barnhart-Magen, G., Gotlib, V., Marilus, R., & Einav, Y.
- Venue
- Journal of Clinical Laboratory Analysis
- Publisher
- Wiley
- Published
- 2013-11
- Volume
- 27
- Issue
- 6
- Pages
- 481-486
- ISSN
- 0887-8013 (ISSN-L)
- OpenAlex
- W1588567921
- Cited by
- 28
- References
- 0
- FWCI
- 0.15
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Differential Diagnostics of Thalassemia Minor by Artificial Neural Networks Model: New Screening Tool for Thalassemia Minor. https://app.cochat.ai/papers/10.1002/jcla.21631
- The paper
- Barnhart-Magen, G., Gotlib, V., Marilus, R., & Einav, Y. (2013). Differential Diagnostics of Thalassemia Minor by Artificial Neural Networks Model: New Screening Tool for Thalassemia Minor. Journal of Clinical Laboratory Analysis. https://doi.org/10.1002/jcla.21631
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.