Semiquantitative, fully automated urine test strip analysis

Open access
Oyaert, Matthijs, Delanghe, Joris R.·2019·Journal of Clinical Laboratory Analysis

Abstract

Objectives: Urinalysis is one of the most frequently ordered diagnostic laboratory tests. In order to reduce workload and costs, rapid screening tests such as urine test strip analyses are applied. The aim of this study was to evaluate the analytical performance of the UC‐3500 as well as the diagnostic performance in comparison with reference methods. Design and methods: We measured within‐run and between‐run imprecision based on quantitative reflectance values. 347 prospectively included urine specimens were investigated for the presence of glucose, protein, albumin, leukocyte esterase, and hemoglobin peroxidase activity, and ordinal scale results were compared to an automated urine particle analyzer (UF‐5000, Sysmex, Kobe, Japan) and wet chemistry (Roche Cobas 8000, Mannheim, Germany). Results: Within‐run and between‐run imprecision results based on reflectance data for both the 9 and 11 parameter test strips ranged from 0.07% to 1.36% for the low‐level control and from 0.37% to 6.13% for the high‐level control, depending on the parameter. Regarding diagnostic performance, the sensitivity/specificity for glucose, protein, albumin, leukocyte esterase, and hemoglobin peroxidase was 100/60%, 94.2/88.2%, 81.8/89.2%, 81.7/92.8%, and 85.1/88.6%, respectively; the negative predictive value was 100%, 83.3%, 89.1%, 94.6%, and 96.1%. The Spearman correlation coefficients of the UC‐3500 vs reference methods ranged from 0.915 to 0.967, depending on the parameter. Conclusion: This fully automated urine test strip analyzer overall shows a satisfying performance and can reliably screen out negative urine samples in order to focus on further characterization of positive samples in the following steps of the workflow.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jcla.22870

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

The citation lists haven’t been fetched yet

References 17 · Cited by 65

Research works printed but not linked: 16

  1. 10.1179/acb.2010.038 · DOI
  2. European Urinalysis Guidelines, 2000, Scand, J Clin Lab Invest Suppl, 231, 1
  3. 10.3343/alm.2019.39.1.15 · DOI
  4. 10.1016/S0009-8981(00)00256-4 · DOI
  5. Rowell DM, 1998, Evaluation of a urine chemistry analyser, Prof Nurse, 13, 533
  6. 10.1016/j.cca.2017.05.032 · DOI
  7. Svendsen PA, 1981, Microalbuminuria in diabetic patients: a longitudinal study, Acta Endocrinol Suppl (Copenh), 242, 53
  8. 10.1111/j.1523-1755.2005.00365.x · DOI
  9. 10.1016/S0272-6386(03)00826-6 · DOI
  10. 10.1053/j.ajkd.2012.06.017 · DOI
  11. 10.1515/cclm-2017-1159 · DOI
  12. 10.1016/j.cca.2017.07.028 · DOI
  13. Fink PC, 1989, Measurement of proteins with the behring nephelometer. A multicenter evaluation, J Clin Chem Clin Biochem, 27, 261
  14. 10.1515/cclm.2012.0849 · DOI
  15. Penders J, 2002, Quantitative evaluation of urinalysis test strips, Clin Chem, 48, 2236, 10.1093/clinchem/48.12.2236 · DOI
  16. 10.1016/j.plabm.2016.03.002 · DOI

Metadata

Authors
Oyaert, M., & Delanghe, J. R.
Affiliations
Ghent University Hospital (BE)
Corresponding author
Oyaert, Matthijs
Venue
Journal of Clinical Laboratory Analysis
Publisher
Wiley
Published
2019-02-25
Volume
33
Issue
5
Pages
e22870-e22870
ISSN
  • 0887-8013 (ISSN-L)
  • 1098-2825
OpenAlex
W2915647281
Cited by
65
References
17
Citations by year
2026: 9 · 2025: 8 · 2024: 10 · 2023: 12 · 2022: 8 · 2021: 10 · 2020: 5 · 2019: 3
FWCI
4.46
Type
journal article
Language
en
Open access
Locations
  • Journal of Clinical Laboratory Analysis (publishedVersion, cc-by-nc-nd)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by-nc-nd)
  • PubMed Central (publishedVersion, cc-by-nc-nd)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
  • Health Sciences › Medicine › Microbiology (medical) › Bacterial Identification and Susceptibility Testing
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced Biosensing Techniques and Applications
Keywords
automated urine analysis, reflectometry, analytical imprecision, diagnostic performance, glucose, proteins, albumin, leukocyte esterase, rapid screening test
MeSH terms
Carboxylic Ester Hydrolases, Glycosuria, Humans, Proteinuria, Reagent Strips, Sensitivity and Specificity, Urinalysis, Automation, Laboratory

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review