Estimation of fetal weight by ultrasound
The DOI matches its Crossref record.
Abstract
Birth weight (BW) and log 10 birth weight (LBW) are expressed as linear, multilinear, parabolic, and polynomial regression functions of the abdominal circumference (AC), and combinations of fetal index measurements, namely, AC and head circumference (HC); biparietal diameter (BPD) and AC; and BPD, HC, and AC. The relationship of somatic weight and log 10 somatic weight to AC was similarly determined. The analysis generated 20 equations whose accuracy in providing BW estimates is compared. Several equations provide BW estimates whose mean percentage deviations from measured BWs do not differ significantly. The deviations, however, have the smallest variance when BW is estimated from the HC and AC either by using a multilinear regression equation or by deriving separate estimates of brain and somatic weights from these index measurements. The role of individual and population differences in fetal anthropometry as causes of error in estimating BW by different methods is discussed. Because HC is a function of both BPD and occipito‐frontal diameter (OFD), it is a better brain‐size modulus than the commonly used BPD and avoids the errors of underestimation which occur when the BPD is unusually small in cases of dolichocephaly. A comparison of ponderal growth in American and South African fetal populations shows differences throughout most of the gestational range (26–40 wk) analyzed in this study.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A systematic review of the ultrasound estimation of fetal weight
Dudley, N. J. (2005) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.1751 · Cited by 537
Hammami, A., Mazer Zumaeta, A., Syngelaki, A., Akolekar, R., & Nicolaides, K. H. (2018) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.19066 · Cited by 170
“Details of the 45 included studies on a total of 70 formulas for EFW are provided in Table 3.(1,3-46) In 33 (71.”
BackgroundMethodResultSonographic Fetal Weight Estimation: Which Model Should Be Used?
Melamed, N., Yogev, Y., Meizner, I., Mashiach, R., Bardin, R., & Ben-Haroush, A. (2009) · Journal of Ultrasound in Medicine · doi:10.7863/jum.2009.28.5.617 · Cited by 112
“Models were subdivided into 7 model groups according to the combination of fetal biometric indices incorporated in each model (Table 1): (1) AC; (2) AC and FL; (3) AC and BPD; (4) AC and HC or AC, HC, and BPD; (5) AC, FL, and BPD; (6) AC, FL, and HC; and (7) AC, FL, BPD, and HC.”
BackgroundMethodResultInfluentialDavid, C., Tagliavini, G., Pilu, G., Rudenholz, A., & Bovicelli, L. (1996) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(96)70347-2 · Cited by 62
Metadata
- Authors
- Jordaan, H. V. F.
- Venue
- Journal of Clinical Ultrasound
- Publisher
- Wiley
- Published
- 1983-02
- Volume
- 11
- Issue
- 2
- Pages
- 59-66
- ISSN
- 0091-2751 (ISSN-L)
- 1097-0096
- OpenAlex
- W2052576929
- Cited by
- 74
- References
- 0
- FWCI
- 2.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Estimation of fetal weight by ultrasound. https://app.cochat.ai/papers/10.1002/jcu.1870110202
- The paper
- Jordaan, H. V. F. (1983). Estimation of fetal weight by ultrasound. Journal of Clinical Ultrasound. https://doi.org/10.1002/jcu.1870110202
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.