Distance measurement by circular scanning of the excitation beam in the two‐photon microscope
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
We developed a method to measure relative distances with nanometer accuracy of fluorescent particles of different color in a two‐photon scanning fluorescence microscope, with two‐channel photon counting detection. The method can be used in the 10–500 nm range, for distances below the resolution limit of standard far field microscopy. The proposed technique is more efficient than the methods using raster scanning. To achieve maximum sensitivity in the radial direction, the excitation beam is moved periodically in a circular orbit with a radius of the size of the point spread function. The phase and the modulation of the periodic fluorescence signal, calculated by fast Fourier transform, gives the phase and the radial distance of the particle from the center of scanning. The coordinates of particles are recovered simultaneously in the two channels and the relative distance is calculated in real time. Particles can be tracked by moving the center of scanning to the recovered position, while measuring the distance from the second particle. Intensity data are saved and fitted later by a model accounting for light leakage between the channels. The total number of detected photons limited the accuracy of the position and distance measurement. Experiments demonstrating the advantages of the method were performed on fluorescent spheres and single dye molecules immobilized on quartz surface. Microsc. Res. Tech. 63:34–49, 2004. © 2003 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fluorescence microscopy with diffraction resolution barrier broken by stimulated emission
Klar, T. A., Jakobs, S., Dyba, M., Egner, A., & Hell, S. W. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.15.8206 · Cited by 1,869 · cited 1×
“Recent advances in optics, based on new physical concepts, reduced the diffraction limit to around 100 nm in the z direction by increasing the aperture in the 4-Pi microscope (Hell, 1994) or by engineering the intensity distribution in the focal spot by stimulated emission (Klar et al., 2000).”
BackgroundMultiphoton microscopy in life sciences
König, K. (2000) · Journal of Microscopy · doi:10.1046/j.1365-2818.2000.00738.x · Cited by 1,265 · cited 1×
“There are unique advantages to apply two-photon excitation, as the inherent selection of the sub-volume without the need of confocal pinholes and the reduced background detection of laser scatter compared with one photon excitation (Denk et al., 1990; Konig, 2000).”
BackgroundKinesin Takes One 8-nm Step for Each ATP That It Hydrolyzes
Coy, D. L., Wagenbach, M., & Howard, J. (1999) · Journal of Biological Chemistry · doi:10.1074/jbc.274.6.3667 · Cited by 390 · cited 1×
“Molecular motors as kinesin move with a load (200 nm) with a velocity on the order of 800 nm/second (Coy et al., 1999).”
Background
Cited by
Tailoring of arbitrary optical vector beams
Maurer, C., Jesacher, A., Fürhapter, S., Bernet, S., & Ritsch-Marte, M. (2007) · New Journal of Physics · doi:10.1088/1367-2630/9/3/078 · Cited by 609
Single Particle Tracking: From Theory to Biophysical Applications
Shen, H., Tauzin, L. J., Baiyasi, R., Wang, W., Moringo, N., Shuang, B., & Landes, C. F. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00815 · Cited by 536
Levi, V., Ruan, Q., & Gratton, E. (2005) · Biophysical Journal · doi:10.1529/biophysj.104.044230 · Cited by 262
Self-citationRuthardt, N., Lamb, D. C., & Bräuchle, C. (2011) · Molecular Therapy · doi:10.1038/mt.2011.102 · Cited by 258
Single-Virus Tracking: From Imaging Methodologies to Virological Applications
Liu, S.-L., Wang, Z.-G., Xie, H.-Y., Liu, A.-A., Lamb, D. C., & Pang, D.-W. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00692 · Cited by 224
“422 For determining the z-position of the fluorescent particle, the difference is taken of the fluorescence intensity between two different z-planes separated by approximately half the axial width of the point-spread function.”
Background
Metadata
- Authors
- Kis‐Petikova, K., & Gratton, E.
- Venue
- Microscopy Research and Technique
- Publisher
- Wiley
- Published
- 2003-12-10
- Volume
- 63
- Issue
- 1
- Pages
- 34-49
- ISSN
- 1059-910X (ISSN-L)
- 1097-0029
- OpenAlex
- W2050484267
- Cited by
- 73
- References
- 3
- FWCI
- 1.60
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.