The DOI matches its Crossref record.
Characterization of two‐photon excitation fluorescence lifetime imaging microscopy for protein localization
Open accessAbstract
Two‐photon excitation fluorescence resonance energy transfer (2P‐FRET) imaging microscopy can provide details of specific protein molecule interactions inside living cells. Fluorophore molecules used for 2P‐FRET imaging have characteristic absorption and emission spectra that introduce spectral cross‐talk (bleed‐through) in the FRET signal that should be removed in the 2P‐FRET images, to establish that FRET has actually occurred and to have a basis for distance estimations. These contaminations in the FRET signal can be corrected using a mathematical algorithm to extract the true FRET signal. Another approach is 2P‐FRET fluorescence lifetime imaging (FLIM). This methodology allows studying the dynamic behavior of protein‐protein interactions in living cells and tissues. 2P‐FRET‐FLIM was used to study the dimerization of the CAATT/enhancer binding protein α (C/EBPα). Results show that the reduction in donor lifetime in the presence of acceptor reveals the dimerization of the protein molecules and also determines more precisely the distance between the donor and acceptor. We describe the development and characterization of the 2P‐FRET‐FLIM imaging system with the Bio‐Rad Radiance2100 confocal/multiphoton microscopy system. Microsc. Res. Tech. 63:72–80, 2004. © 2003 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fluorescence Lifetime Measurements and Biological Imaging
Berezin, M. Y., & Achilefu, S. (2010) · Chemical Reviews · doi:10.1021/cr900343z · Cited by 2,403
Yao, J., Yang, M., & Duan, Y. (2014) · Chemical Reviews · doi:10.1021/cr200359p · Cited by 944
Fluorescence lifetime imaging – techniques and applications
BECKER, W. (2012) · Journal of Microscopy · doi:10.1111/j.1365-2818.2012.03618.x · Cited by 890
Imaging protein molecules using FRET and FLIM microscopy
Wallrabe, H., & Periasamy, A. (2005) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2004.12.002 · Cited by 724
Self-citationHeterodimerization and Endocytosis of Arabidopsis Brassinosteroid Receptors BRI1 and AtSERK3 (BAK1)
Russinova, E., Borst, J.-W., Kwaaitaal, M., Caño-Delgado, A., Yin, Y., Chory, J., & de Vries, S. C. (2004) · The Plant Cell · doi:10.1105/tpc.104.025387 · Cited by 478
Metadata
- Authors
- Chen, Y., & Periasamy, A.
- Venue
- Microscopy Research and Technique
- Publisher
- Wiley
- Published
- 2003-12-10
- Volume
- 63
- Issue
- 1
- Pages
- 72-80
- ISSN
- 1059-910X (ISSN-L)
- 1097-0029
- OpenAlex
- W2156038004
- Cited by
- 164
- References
- 0
- FWCI
- 6.41
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Characterization of two‐photon excitation fluorescence lifetime imaging microscopy for protein localization. https://app.cochat.ai/papers/10.1002/jemt.10430
- The paper
- Chen, Y., & Periasamy, A. (2004). Characterization of two‐photon excitation fluorescence lifetime imaging microscopy for protein localization. Microscopy Research and Technique. https://doi.org/10.1002/jemt.10430
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.