CoChat

Continuous serial thin sectioning for electron microscopy

Fahrenbach, Wolf H. · 1984 · Journal of Electron Microscopy Technique
Cited by 38

The DOI matches its Crossref record.

Abstract

The process of serial sectioning for electron microscopy has been refined such that loss of thin sections is kept below 0.1% and the series is continued at will. The method relies on microscopic control of all manipulative steps, Formvar casting on plate glass for coated slot grids, coating of the block with contact cement for reliable ribboning, pickup by a one‐step method with grid support in the diamond knife trough, staining in LKB grid holders, gentle treatment of grids in the electron microscope, and a slight modification to the microscope for safe grid withdrawal. The results are particularly applicable to the reconstruction of neuronal microcircuits and larger volumes of neuropil.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jemt.1060010407

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 38

Metadata

Authors
Fahrenbach, W. H.
Venue
Journal of Electron Microscopy Technique
Publisher
Wiley
Published
1984-01
Volume
1
Issue
4
Pages
387-398
ISSN
  • 0741-0581 (ISSN-L)
  • 1553-0817
OpenAlex
W2090326447
Cited by
38
References
0
FWCI
1.92
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Continuous serial thin sectioning for electron microscopy. https://app.cochat.ai/papers/10.1002/jemt.1060010407
The paper
Fahrenbach, W. H. (1984). Continuous serial thin sectioning for electron microscopy. Journal of Electron Microscopy Technique. https://doi.org/10.1002/jemt.1060010407