Continuous serial thin sectioning for electron microscopy
The DOI matches its Crossref record.
Abstract
The process of serial sectioning for electron microscopy has been refined such that loss of thin sections is kept below 0.1% and the series is continued at will. The method relies on microscopic control of all manipulative steps, Formvar casting on plate glass for coated slot grids, coating of the block with contact cement for reliable ribboning, pickup by a one‐step method with grid support in the diamond knife trough, staining in LKB grid holders, gentle treatment of grids in the electron microscope, and a slight modification to the microscope for safe grid withdrawal. The results are particularly applicable to the reconstruction of neuronal microcircuits and larger volumes of neuropil.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Synaptic organization of columnar elements in the lamina of the wild type in Drosophila melanogaster
Meinertzhagen, I. A., & O'Neil, S. D. (1991) · Journal of Comparative Neurology · doi:10.1002/cne.903050206 · Cited by 403
Chapter 17 Electron Microscopy and Three-Dimensional Image Reconstruction
Hall, D. H. (1995) · Methods in Cell Biology · doi:10.1016/s0091-679x(08)61397-7 · Cited by 166
Rivlin, P. K., & Raymond, P. A. (1987) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(87)90036-7 · Cited by 24
Metadata
- Authors
- Fahrenbach, W. H.
- Venue
- Journal of Electron Microscopy Technique
- Publisher
- Wiley
- Published
- 1984-01
- Volume
- 1
- Issue
- 4
- Pages
- 387-398
- ISSN
- 0741-0581 (ISSN-L)
- 1553-0817
- OpenAlex
- W2090326447
- Cited by
- 38
- References
- 0
- FWCI
- 1.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Continuous serial thin sectioning for electron microscopy. https://app.cochat.ai/papers/10.1002/jemt.1060010407
- The paper
- Fahrenbach, W. H. (1984). Continuous serial thin sectioning for electron microscopy. Journal of Electron Microscopy Technique. https://doi.org/10.1002/jemt.1060010407
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.