The DOI matches its Crossref record.
PixFRET, an ImageJ plug‐in for FRET calculation that can accommodate variations in spectral bleed‐throughs
Open accessAbstract
Fluorescence resonance energy transfer (FRET) allows the user to investigate interactions between fluorescent partners. One crucial issue when calculating sensitized emission FRET is the correction for spectral bleed‐throughs (SBTs), which requires to calculate the ratios between the intensities in the FRET and in the donor or acceptor settings, when only the donor or acceptor are present. Theoretically, SBT ratios should be constant. However, experimentally, these ratios can vary as a function of fluorophore intensity, and assuming constant values may hinder precise FRET calculation. One possible cause for such a variation is the use of a microscope set‐up with different photomultipliers for the donor and FRET channels, a set‐up allowing higher speed acquisitions on very dynamic fluorescent molecules in living cells. Herein, we show that the bias introduced by the differential response of the two PMTs can be circumvented by a simple modeling of the SBT ratios as a function of fluorophore intensity. Another important issue when performing FRET is the localization of FRET within the cell or a population of cells. We hence developed a freely available ImageJ plug‐in, called PixFRET, that allows a simple and rapid determination of SBT parameters and the display of normalized FRET images. The usefulness of this modeling and of the plug‐in are exemplified by the study of FRET in a system where two interacting nuclear receptors labeled with ECFP and EYFP are coexpressed in living cells. Microsc. Res. Tech. 68:51–58, 2005. © 2005 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Advanced Fluorescence Microscopy Techniques—FRAP, FLIP, FLAP, FRET and FLIM
Ishikawa-Ankerhold, H. C., Ankerhold, R., & Drummen, G. P. C. (2012) · Molecules · doi:10.3390/molecules17044047 · Cited by 557
High-Sensitivity Measurements of Multiple Kinase Activities in Live Single Cells
Regot, S., Hughey, J. J., Bajar, B. T., Carrasco, S., & Covert, M. W. (2014) · Cell · doi:10.1016/j.cell.2014.04.039 · Cited by 551
Feige, J. N., Gelman, L., Rossi, D., Zoete, V., Métivier, R., Tudor, C., Anghel, S. I., Grosdidier, A., Lathion, C., Engelborghs, Y., et al. (2007) · Journal of Biological Chemistry · doi:10.1074/jbc.m702724200 · Cited by 356
Self-citationSrinivasan, R., Pantoja, R., Moss, F. J., Mackey, E. D. W., Son, C. D., Miwa, J., & Lester, H. A. (2011) · Journal of General Physiology · doi:10.1085/jgp.201010532 · Cited by 169
Tong, B. C.-K., Lee, C. S.-K., Cheng, W.-H., Lai, K.-O., Kevin Foskett, J., & Cheung, K.-H. (2016) · Science Signaling · doi:10.1126/scisignal.aaf1371 · Cited by 87
Metadata
- Authors
- Feige, J. N., Sage, D., Wahli, W., Desvergne, B., & Gelman, L.
- Venue
- Microscopy Research and Technique
- Publisher
- Wiley
- Published
- 2005-09
- Volume
- 68
- Issue
- 1
- Pages
- 51-58
- ISSN
- 1059-910X (ISSN-L)
- 1097-0029
- OpenAlex
- W2160005499
- Cited by
- 215
- References
- 0
- FWCI
- 4.69
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: PixFRET, an ImageJ plug‐in for FRET calculation that can accommodate variations in spectral bleed‐throughs. https://app.cochat.ai/papers/10.1002/jemt.20215
- The paper
- Feige, J. N., Sage, D., Wahli, W., Desvergne, B., & Gelman, L. (2005). PixFRET, an ImageJ plug‐in for FRET calculation that can accommodate variations in spectral bleed‐throughs. Microscopy Research and Technique. https://doi.org/10.1002/jemt.20215
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.