Direct observation of liquid crystals using cryo‐TEM: Specimen preparation and low‐dose imaging
Open accessThe DOI matches its Crossref record.
Abstract
Liquid crystals (LCs) represent a challenging group of materials for direct transmission electron microscopy (TEM) studies due to the complications in specimen preparation and the severe radiation damage. In this paper, we summarize a series of specimen preparation methods, including thin film and cryo‐sectioning approaches, as a comprehensive toolset enabling high‐resolution direct cryo‐TEM observation of a broad range of LCs. We also present comparative analysis using cryo‐TEM and replica freeze‐fracture TEM on both thermotropic and lyotropic LCs. In addition to the revisits of previous practices, some new concepts are introduced, e.g., suspended thermotropic LC thin films, combined high‐pressure freezing and cryo‐sectioning of lyotropic LCs, and the complementary applications of direct TEM and indirect replica TEM techniques. The significance of subnanometer resolution cryo‐TEM observation is demonstrated in a few important issues in LC studies, including providing direct evidences for the existence of nanoscale smectic domains in nematic bent‐core thermotropic LCs, comprehensive understanding of the twist‐bend nematic phase, and probing the packing of columnar aggregates in lyotropic chromonic LCs. Direct TEM observation opens ways to a variety of TEM techniques, suggesting that TEM (replica, cryo, and in situ techniques), in general, may be a promising part of the solution to the lack of effective structural probe at the molecular scale in LC studies. Microsc. Res. Tech. 77:754–772, 2014. © 2014 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Dorayappan, K. D. P., Wanner, R., Wallbillich, J. J., Saini, U., Zingarelli, R., Suarez, A. A., Cohn, D. E., & Selvendiran, K. (2018) · Oncogene · doi:10.1038/s41388-018-0189-0 · Cited by 306
Mentkowski, K. I., & Lang, J. K. (2019) · Scientific Reports · doi:10.1038/s41598-019-46407-1 · Cited by 244
Biodegradable Amino-Ester Nanomaterials for Cas9 mRNA Delivery in Vitro and in Vivo
Zhang, X., Li, B., Luo, X., Zhao, W., Jiang, J., Zhang, C., Gao, M., Chen, X., & Dong, Y. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b08163 · Cited by 107
Self-citationPutta, P., Rankenberg, J., Korver, R. A., van Wijk, R., Munnik, T., Testerink, C., & Kooijman, E. E. (2016) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/j.bbamem.2016.07.014 · Cited by 95
Metadata
- Authors
- Gao, M., Kim, Y., Zhang, C., Borshch, V., Zhou, S., Park, H., Jákli, A., Lavrentovich, O. D., Tamba, M., Kohlmeier, A., Mehl, G. H., Weissflog, W., Studer, D., Zuber, B., Gnägi, H., & Lin, F.
- Venue
- Microscopy Research and Technique
- Publisher
- Wiley
- Published
- 2014-07-05
- Volume
- 77
- Issue
- 10
- Pages
- 754-772
- ISSN
- 1059-910X (ISSN-L)
- 1097-0029
- OpenAlex
- W1555934055
- Cited by
- 104
- References
- 0
- FWCI
- 4.49
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Direct observation of liquid crystals using cryo‐TEM: Specimen preparation and low‐dose imaging. https://app.cochat.ai/papers/10.1002/jemt.22397
- The paper
- Gao, M., Kim, Y., Zhang, C., Borshch, V., Zhou, S., Park, H., Jákli, A., Lavrentovich, O. D., Tamba, M., Kohlmeier, A., Mehl, G. H., Weissflog, W., Studer, D., Zuber, B., Gnägi, H., & Lin, F. (2014). Direct observation of liquid crystals using cryo‐TEM: Specimen preparation and low‐dose imaging. Microscopy Research and Technique. https://doi.org/10.1002/jemt.22397
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.