The DOI matches its Crossref record.
Factors affecting the reversed‐phase liquid chromatographic separation of polycyclic aromatic hydrocarbon isomers
Abstract
Reversed‐phase liquid chromatography (LC) on C 18 stationary phases provides excellent selectivity for the separation of polycyclic aromatic hydrocarbons (PAH). Recent studies have shown that several factors affect selectivity for the LC separation of PAH including phase type (monomeric or polymeric), pore diameter and surface area of the silica substrate, and surface density of the C 18 ligands. In this paper the separation of eleven PAH isomers of molecular weight 278 is used to further illustrate the effect of stationary phase characteristics and shape of the solute (length‐to‐breadth ratio, L/B) on retention and selectivity. Only polymeric C 18 phases with a high C 18 surface coverage provided separation of all eleven isomers and the elution order of these isomers generally followed increasing L/B values. The effect of solute nonplanarity on reversed‐phase LC retention was investigated on both monomeric and polymeric phases using a series of planar and nonplanar PAH pairs. For each solute pair, the nonplanar solute eluted earlier than the planar solute, the largest selectivity factors being observed on the C 18 phase with the highest percent carbon load. Based on these studies, a model is proposed to describe the retention of PAH on polymeric C 18 phases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Development of Engineered Stationary Phases for the Separation of Carotenoid Isomers
Sander, L. C., Sharpless, K. E., Craft, N. E., & Wise, S. A. (1994) · Analytical Chemistry · doi:10.1021/ac00082a012 · Cited by 363
Self-citationŽuvela, P., Skoczylas, M., Jay Liu, J., Ba̧czek, T., Kaliszan, R., Wong, M. W., & Buszewski, B. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00246 · Cited by 354
Solid Phase Microextraction Coupled to High-Performance Liquid Chromatography
Chen, J., & Pawliszyn, J. B. (1995) · Analytical Chemistry · doi:10.1021/ac00111a006 · Cited by 310
Metadata
- Authors
- Wise, S. A., & Sander, L. C.
- Venue
- Journal of High Resolution Chromatography
- Publisher
- Wiley
- Published
- 1985-05
- Volume
- 8
- Issue
- 5
- Pages
- 248-255
- ISSN
- 0935-6304 (ISSN-L)
- 1521-4168
- OpenAlex
- W2166168987
- Cited by
- 223
- References
- 0
- FWCI
- 10.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Factors affecting the reversed‐phase liquid chromatographic separation of polycyclic aromatic hydrocarbon isomers. https://app.cochat.ai/papers/10.1002/jhrc.1240080506
- The paper
- Wise, S. A., & Sander, L. C. (1985). Factors affecting the reversed‐phase liquid chromatographic separation of polycyclic aromatic hydrocarbon isomers. Journal of High Resolution Chromatography. https://doi.org/10.1002/jhrc.1240080506
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.