The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Complete PCB congener distributions for 17 aroclor mixtures determined by 3 HRGC systems optimized for comprehensive, quantitative, congener‐specific analysis
Abstract
Three HRGC systems (1: 30m DB‐XLB capillary with MS‐SIM detection; 2: 60m DB‐XLB capillary with full‐scan, ion‐trap MS detection; and 3: Parallel dual‐column DB‐17 and series‐coupled HP5/HT5 with ECD detection) were used to completely characterize multiple lots of 8 different‐numbered Aroclor mixtures by quantitative calibration against 9 solutions containing primary standards of all 209 PCB congeners. Despite lower absolute sensitivity and more Aroclor congener coelutions than the dual‐column ECD system, the MS systems enabled measurement of more congeners per Aroclor since their greater linear response range did not require dilution of samples and standards. Pairs of different lots of Aroclors 1248 and 1254 displayed markedly different proportions of congeners, and the 1254 pair displayed strong differences in the extent of ortho‐chlorine substitution. The tables of congener weight percent distributions among Aroclors are more comprehensive and quantitatively precise than those of prior publications. However, the limitations of single‐level calibration precluded measurement of all congeners to the ±10% accuracy desirable for establishing these Aroclors as secondary standards for comprehensive, quantitative congener‐specific PCB analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ballschmiter, K., & Zell, M. (1980) · Fresenius' Zeitschrift für analytische Chemie · doi:10.1007/bf00469758 · Cited by 1,437
McFarland, V. A., & Clarke, J. U. (1989) · Environmental Health Perspectives · doi:10.1289/ehp.8981225 · Cited by 714
Schulz, D. E., Petrick, G., & Duinker, J. C. (1989) · Environmental Science & Technology · doi:10.1021/es00065a015 · Cited by 628
Bedard, D. L., Wagner, R. E., Brennan, M. J., Haberl, M. L., & Brown, J. F. (1987) · Applied and Environmental Microbiology · doi:10.1128/aem.53.5.1094-1102.1987 · Cited by 256
Frame, G. M., Wagner, R. E., CARNAHAN, J. C. J., Brown, J. F., May, R. J., Smullen, L. A., & Bedard, D. L. (1996) · Chemosphere · doi:10.1016/0045-6535(96)00214-7 · Cited by 187
Self-citation
Cited by
Lowry, G. V., & Johnson, K. M. (2004) · Environmental Science & Technology · doi:10.1021/es049835q · Cited by 362
Stepping backward to improve assessment of PCB congener toxicities.
Hansen, L. G. (1998) · Environmental Health Perspectives · doi:10.1289/ehp.98106s1171 · Cited by 336
Methyl Sulfone and Hydroxylated Metabolites of Polychlorinated Biphenyls
Letcher, R. J., Klasson-Wehler, E., & Bergman, A. (2000) · Volume 3 Anthropogenic Compounds Part K · doi:10.1007/3-540-48915-0_11 · Cited by 262
Zoeller, R. T., Dowling, A. L. S., & Vas, A. A. (2000) · Endocrinology · doi:10.1210/endo.141.1.7273 · Cited by 168
Howard, A. (2003) · Toxicology and Applied Pharmacology · doi:10.1016/s0041-008x(03)00156-x · Cited by 112
Metadata
- Authors
- Frame, G. M., Cochran, J. W., & Bøwadt, S. S.
- Venue
- Journal of High Resolution Chromatography
- Publisher
- Wiley
- Published
- 1996-12
- Volume
- 19
- Issue
- 12
- Pages
- 657-668
- ISSN
- 0935-6304 (ISSN-L)
- 1521-4168
- OpenAlex
- W2065346737
- Cited by
- 553
- References
- 5
- FWCI
- 10.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.