CoChat

cGMP production of the radiopharmaceutical [18F]MK‐6240 for PET imaging of human neurofibrillary tangles

Collier, Thomas Lee, Yokell, Daniel L., Livni, Eli, Rice, Peter A., Celen, Sofie, Serdons, Kim, Neelamegam, Ramesh, Bormans, Guy, Harris, Dawn, Walji, Abbas, Hostetler, Eric D., Bennacef, Idriss, Vasdev, Neil · 2017 · Journal of Labelled Compounds and Radiopharmaceuticals
Cited by 36

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

Fluorine‐18–labelled 6‐(fluoro)‐3‐(1H‐pyrrolo[2,3‐c]pyridin‐1‐yl)isoquinolin‐5‐amine ([18 F]MK‐6240) is a novel potent and selective positron emission tomography (PET) radiopharmaceutical for detecting human neurofibrillary tangles, which are made up of aggregated tau protein. Herein, we report the fully automated 2‐step radiosynthesis of [18 F]MK‐6240 using a commercially available radiosynthesis module, GE Healthcare TRACERlab FX FN. Nucleophilic fluorination of the 5‐diBoc‐6‐nitro precursor with potassium cryptand [18 F]fluoride (K[18 F]/K 222) was performed by conventional heating, followed by acid deprotection and semipreparative high‐performance liquid chromatography under isocratic conditions. The isolated product was diluted with formulation solution and sterile filtered under Current Good Manufacturing Practices, and quality control procedures were established to validate this radiopharmaceutical for human use. At the end of synthesis, 6.3 to 9.3 GBq (170‐250 mCi) of [18 F]MK‐6240 was formulated and ready for injection, in an uncorrected radiochemical yield of 7.5% ± 1.9% (relative to starting [18 F]fluoride) with a specific activity of 222 ± 67 GBq/μmol (6.0 ± 1.8 Ci/μmol) at the end of synthesis (90 minutes; n = 3). [18 F]MK‐6240 was successfully validated for human PET studies meeting all Food and Drug Administration and United States Pharmacopeia requirements for a PET radiopharmaceutical. The present method can be easily adopted for use with other radiofluorination modules for widespread clinical research use.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jlcr.3496

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

Metadata

Authors
Collier, T. L., Yokell, D. L., Livni, E., Rice, P. A., Celen, S., Serdons, K., Neelamegam, R., Bormans, G., Harris, D., Walji, A., Hostetler, E. D., Bennacef, I., & Vasdev, N.
Venue
Journal of Labelled Compounds and Radiopharmaceuticals
Publisher
Wiley
Published
2017-03-23
Volume
60
Issue
5
Pages
263-269
ISSN
  • 0362-4803 (ISSN-L)
  • 1099-1344
OpenAlex
W2587506740
Cited by
36
References
7
FWCI
2.84
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.