Cited by 73Advanced MRI Techniques and ApplicationsBody Composition Measurement TechniquesNMR spectroscopy and applications

Lipid content in the musculature of the lower leg assessed by fat selective MRI: Intra‐ and interindividual differences and correlation with anthropometric and metabolic data

Open access
Machann, Jürgen, Bachmann, Oliver P., Brechtel, Klaus, Dahl, Dominik B., Wietek, Beate, Klumpp, Bernhard, Häring, Hans‐U., Claussen, Claus D. +2 more·2003·Journal of Magnetic Resonance Imaging

Abstract

Purpose: To assess the muscular lipid content (LC) in different muscle groups of the lower leg by a magnetic resonance imaging technique working with chemical shift selective excitation, and comparison with anthropometric and metabolic data. Materials and Methods: Examinations were performed in 67 volunteers (54 male/13 female, age 29 ± seven years) on a 1.5 T whole body imager, applying a highly selective spectral‐spatial technique for fat selective MRI. LC was measured in six calf muscles and correlated with body mass index (BMI), percent body fat (PFAT), and insulin sensitivity (IS) of the subjects. Results: Mean muscular LC of all subjects was between 2.0% (Tibialis posterior [TP]) and 3.8% (Peroneus muscles) with female subjects showing a significantly higher LC in all muscle groups (P < 0.05 each). LCs correlated moderately with BMI (R between 0.39 [TP] and 0.53 [GM]) and with PFAT (R between 0.38 [TP] and 0.62 [GM]). Insulin‐resistant subjects showed slightly but not significantly increased LC compared to insulin‐sensitive subjects in BMI‐matched subgroups. Conclusion: The fat‐selective MRI technique allows a reliable non‐invasive measure of muscular lipids – even in muscle groups with inherent low LC – within a relatively short measurement time of about three minutes. The presented data reveal interesting interrelationships between LC and anthropometric and metabolic data, and therefore provide new insight into muscular fat metabolism. J. Magn. Reson. Imaging 2003;17:350–357. © 2003 Wiley‐Liss, Inc.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jmri.10255

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Radiation attenuation of muscle shows a high correlation with direct measurements of muscle lipid content by biopsy.

    “While Hounsfield units are not a direct measure of lipid content, the radiation attenuation of muscle shows a high correlation with direct measurements of muscle lipid content by biopsy (Machann et al., 2003; Larson-Meyer et al., 2006).”
  • Parallel with the increase in circulating lipids, the intramyocellular lipid content appears to increase proportionally in obese humans and rodents.

    “Parallel with the increase in circulating lipids, the intramyocellular (IMC) lipid content appears to increase proportionally in obese humans ([105](#B105)) and rodents ([23](#B23)).”

    From Mitochondrial fatty acid oxidation in obesity (2013) · cites this paper as [105]

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 37 · Cited by 73

Research works printed but not linked: 3

  1. Stein DT, Szczepaniak LS, Dobbins RL, Snell P, McGarry JD. Skel- etal muscle triglycerides stores are increased in insulin resistant states In: Proceedings of the 6th Annual Meeting of ISMRM, Sydney, Australia, 1998. p 388.
  2. Laurent WM, Bonny JM, Renou JP. Imaging of water and fat frac- tions in high-field MRI with multiple slice chemical shift-selective inversion recovery. J Magn Reson Imaging 2000;12:488 -496.
  3. Zur Y. Design of improved spectral-spatial pulses for routine clin- ical use. Magn Reson Med 2000;43:410 -420.

Authors
Machann, J., Bachmann, O. P., Brechtel, K., Dahl, D. B., Wietek, B., Klumpp, B., Häring, H., Claussen, C. D., Jacob, S., & Schick, F.
Affiliations
University of Tübingen (DE)
Corresponding author
Machann, Jürgen
Venue
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Published
2003-02-19
Volume
17
Issue
3
Pages
350-357
ISSN
  • 1053-1807 (ISSN-L)
  • 1522-2586
OpenAlex
W2013277513
Cited by
73
References
37
Citations by year
2023: 3 · 2022: 2 · 2021: 4 · 2020: 7 · 2019: 3 · 2018: 2 · 2017: 4 · 2016: 6 · 2015: 3 · 2014: 3 · 2013: 4 · 2012: 4
FWCI
2.48
Type
journal article
Language
en
Open access
Locations
  • Journal of Magnetic Resonance Imaging (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Deutsche Forschungsgemeinschaft (DFG #JA-1005/1)
  • Federal Ministry of Education and Research (Fö. 01KS9602)
  • Interdisciplinary Center of Clinical Research Tübingen (IZKF)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
  • Health Sciences › Medicine › Physiology › Body Composition Measurement Techniques
  • Physical Sciences › Physics and Astronomy › Nuclear and High Energy Physics › NMR spectroscopy and applications
Keywords
muscle fat content, lower leg muscles, tibialis posterior, peroneal muscles, body mass index, body fat percentage, insulin sensitivity, insulin resistance, sex differences, anthropometry, metabolic data
MeSH terms
Adult, Anthropometry, Female, Humans, Leg, Lipids, Magnetic Resonance Imaging, Male, Prospective Studies, Reference Values, Glucose Clamp Technique, Body Mass Index, Sex Distribution, Muscle, Skeletal

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review