The DOI matches its Crossref record.
Effect of static magnetic field exposure of up to 8 Tesla on sequential human vital sign measurements
Open accessAbstract
Purpose: To determine if increasing static magnetic field strength exposures up to 8 Tesla (T) affect vital signs or electrocardiograms (ECGs) in normal human volunteers. Materials and Methods: We studied 25 normal subjects, consisting of 19 men and six women, ages 24–53 years. The vital signs and ECGs of the subjects were measured 14 times inside and outside the magnetic field. This included the heart rate, respiratory rate, systolic and diastolic blood pressures, finger pulse oxygenation levels, core body temperature via the external auditory canal temperature, and fiber optic core body sublingual temperatures. Inside the magnetic field the vital signs were measured sequentially at field strengths of 8, 6, 4.5, 3, and 1.5 T. Results: The only statistically significant effect of magnetic field strength was observed with systolic blood pressure. An average increase of 3.6 mm Hg in systolic blood pressure was seen with 8 T exposure. ECG rhythm strip analysis demonstrated no significant changes post‐exposure. Conclusions: Normal subjects exposed to varying magnetic field strengths of up to 8 T demonstrated no clinically significant changes in vital signs. Transient ECG artifacts were noted to increase with the field strength. J. Magn. Reson. Imaging 2003;18:346–352. © 2003 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
GUIDELINES ON LIMITS OF EXPOSURE TO STATIC MAGNETIC FIELDS
(2009) · Health Physics · doi:10.1097/01.hp.0000343164.27920.4a · Cited by 455
De Wilde, J. P., Rivers, A. W., & Price, D. L. (2005) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2004.08.010 · Cited by 351
Magnetically induced electric fields and currents in the circulatory system
Tenforde, T. S. (2005) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2004.08.003 · Cited by 96
Metadata
- Authors
- Chakeres, D. W., Kangarlu, A., Boudoulas, H., & Young, D. C.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2003-08-18
- Volume
- 18
- Issue
- 3
- Pages
- 346-352
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2139110983
- Cited by
- 161
- References
- 0
- FWCI
- 4.61
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.