The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Pediatric perfusion imaging using pulsed arterial spin labeling
Abstract
Purpose: To test the feasibility of pediatric perfusion imaging using a pulsed arterial spin labeling (ASL) technique at 1.5 T. Materials and Methods: ASL perfusion imaging was carried out on seven neurologically normal children and five healthy adults. The signal‐to‐noise ratio (SNR) of the perfusion images along with T1, M 0, arterial transit time, and the temporal fluctuation of the ASL image series were measured and compared between the two age groups. In addition, ASL perfusion magnetic resonance (MR) was performed on three children with neurologic disorder. Results: In the cohort of neurologically normal children, a 70% increase in the SNR of the ASL perfusion images and a 30% increase in the absolute cerebral blood flow compared to the adult data were observed. The measures of ASL SNR, T1, and M 0 were found to decrease linearly with age. Transit time and temporal fluctuation of the ASL perfusion image series were not significantly different between the two age groups. The feasibility of ASL in the diagnosis of pediatric neurologic disease was also illustrated. Conclusion: ASL is a promising tool for pediatric perfusion imaging given the unique and reciprocal benefits in terms of safety and image quality. J. Magn. Reson. Imaging 2003;18:404–413. © 2003 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantitative growth and development of human brain
Dobbing, J., & Sands, J. (1973) · Archives of Disease in Childhood · doi:10.1136/adc.48.10.757 · Cited by 1,442
Chugani, H. T., & Phelps, M. E. (1986) · Science · doi:10.1126/science.3945811 · Cited by 663
Cited by
Sex differences in the developing brain: insights from multimodal neuroimaging
Kaczkurkin, A. N., Raznahan, A., & Satterthwaite, T. D. (2019) · Neuropsychopharmacology · doi:10.1038/s41386-018-0111-z · Cited by 403
Non-invasive measurement of perfusion: a critical review of arterial spin labelling techniques
Petersen, E. T., Zimine, I., Ho, Y.-C. L., & Golay, X. (2006) · The British Journal of Radiology · doi:10.1259/bjr/67705974 · Cited by 352
Preoperative cerebral blood flow is diminished in neonates with severe congenital heart defects
Licht, D. J., Wang, J., Silvestre, D. W., Nicolson, S. C., Montenegro, L. M., Wernovsky, G., Tabbutt, S., Durning, S. M., Shera, D. M., Gaynor, J. W., et al. (2004) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2004.07.022 · Cited by 332
Self-citationApplications of arterial spin labeled MRI in the brain
Detre, J. A., Rao, H., Wang, D. J. J., Chen, Y. F., & Wang, Z. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23581 · Cited by 326
Self-citationA neuroradiologist’s guide to arterial spin labeling MRI in clinical practice
Grade, M., Hernandez Tamames, J. A., Pizzini, F. B., Achten, E., Golay, X., & Smits, M. (2015) · Neuroradiology · doi:10.1007/s00234-015-1571-z · Cited by 298
Metadata
- Authors
- Wang, J., Licht, D. J., Jahng, G., Liu, C., Rubin, J. T., Haselgrove, J., Zimmerman, R. A., & Detre, J. A.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2003-09-19
- Volume
- 18
- Issue
- 4
- Pages
- 404-413
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2169006766
- Cited by
- 238
- References
- 2
- FWCI
- 4.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pediatric perfusion imaging using pulsed arterial spin labeling. https://app.cochat.ai/papers/10.1002/jmri.10372
- The paper
- Wang, J., Licht, D. J., Jahng, G., Liu, C., Rubin, J. T., Haselgrove, J., Zimmerman, R. A., & Detre, J. A. (2003). Pediatric perfusion imaging using pulsed arterial spin labeling. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.10372
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.