Interscanner reproducibility of cardiovascular magnetic resonance T2* measurements of tissue iron in thalassemia
Open accessAbstract
Purpose: To assess interscanner reproducibility of tissue iron measurements in patients with thalassemia using gradient echo T2* measurements on two different MRI scanners. Materials and Methods: Twenty‐five patients with thalassemia major had liver and myocardial T2* assessment using a Picker Edge 1.5T Scanner and a Siemens Sonata 1.5T scanner, with similar gradient echo sequences. In a subset of 13 patients, two scans on the Siemens scanner were performed to assess interstudy reproducibility. Results: There was a highly significant, linear correlation between T2* values obtained for both the heart (r = 0.95) and the liver (r = 0.99) between scanners. The mean difference, coefficient of variability, and 95% confidence intervals between scanners were 0.8 msec, 9.4% and –5.0 to 6.7 msec for the heart; and 0.9 msec, 7.9% and –2.0 to 3.9 msec for the liver. The interstudy mean difference and coefficient of variability on the Siemens scanner was 0.3 msec and 4.8% (r = 0.99) for the heart, and 0.04 msec and 1.9% (r = 0.99) for the liver. Conclusion: The T2* technique for measuring tissue iron is reproducible between the two manufacturers' scanners. This suggests that the widespread implementation of the technique is possible for clinical assessment of myocardial iron loading in thalassemia. J. Magn. Reson. Imaging 2003;18:616–620. © 2003 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Cited by
Messroghli, D. R., Moon, J. C., Ferreira, V. M., Grosse-Wortmann, L., He, T., Kellman, P., Mascherbauer, J., Nezafat, R., Salerno, M., Schelbert, E. B., et al. (2016) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-017-0389-8 · Cited by 1,727
Wood, J. C., Enriquez, C., Ghugre, N., Tyzka, J. M., Carson, S., Nelson, M. D., & Coates, T. D. (2005) · Blood · doi:10.1182/blood-2004-10-3982 · Cited by 1,045
Imaging iron stores in the brain using magnetic resonance imaging
Haacke, E. M., Cheng, N. Y. C., House, M. J., Liu, Q., Neelavalli, J., Ogg, R. J., Khan, A., Ayaz, M., Kirsch, W., & Obenaus, A. (2005) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2004.10.001 · Cited by 995
Clinical indications for cardiovascular magnetic resonance (CMR): Consensus Panel report?
PENNELL, D. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.06.040 · Cited by 747
Self-citationEzekowitz, J. A., O'Meara, E., McDonald, M. A., Abrams, H., Chan, M., Ducharme, A., Giannetti, N., Grzeslo, A., Hamilton, P. G., Heckman, G. A., et al. (2017) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2017.08.022 · Cited by 676
Metadata
- Authors
- Westwood, M. A., Anderson, L. J., Firmin, D. N., Gatehouse, P. D., Lorenz, C. H., Wonke, B., & Pennell, D. J.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2003-10-20
- Volume
- 18
- Issue
- 5
- Pages
- 616-620
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2073632465
- Cited by
- 166
- References
- 1
- FWCI
- 3.74
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Interscanner reproducibility of cardiovascular magnetic resonance T2* measurements of tissue iron in thalassemia. https://app.cochat.ai/papers/10.1002/jmri.10396
- The paper
- Westwood, M. A., Anderson, L. J., Firmin, D. N., Gatehouse, P. D., Lorenz, C. H., Wonke, B., & Pennell, D. J. (2003). Interscanner reproducibility of cardiovascular magnetic resonance T2* measurements of tissue iron in thalassemia. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.10396
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.