Measurement of abdominal fat with T1‐weighted MR images
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The cross‐sectional area of visceral and subcutaneous fat in the abdomen was measured with T1 weighted spin‐echo images acquired with a 1.5‐T magnetic resonance (MR) imager. Four axial images centered on L‐4 were acquired in each patient. Outline regions of interest (ROIs) were drawn manually for subcutaneous and visceral fat. The subcutaneous fat cross‐sectional area was calculated from the ROIs drawn around the outer and inner margins of subcutaneous fat. Several adaptive processing methods were evaluated for measuring fat in the complex structure of the viscera. These methods were compared with an existing MR imaging measurement method for abdominal fat in 18 patients. The adaptive method that uses the valley between the fat and nonfat distributions in the average histogram curve was judged best for research evaluations because it reduces the effects of volume averaging while using a more natural division between fat and nonfat data. Another adaptive method that yielded comparable measurements was thought to be more suitable for clinical applications. Cross‐sectional area measurements of abdominal fat were compared in 18 nonobese and 17 obese women to illustrate the utility of these measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lean body mass estimation by bioelectrical impedance analysis: a four-site cross-validation study
Segal, K., Van Loan, M., Fitzgerald, P., Hodgdon, A., & Van Itallie, T. (1988) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/47.1.7 · Cited by 881
Enzi, G., Gasparo, M., Biondetti, P., Fiore, D., Semisa, M., & Zurlo, F. (1986) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/44.6.739 · Cited by 547
Seidell, J., Bakker, C., & van der Kooy, K. (1990) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/51.6.953 · Cited by 375
Cited by
Bugianesi, E., Gastaldelli, A., Vanni, E., Gambino, R., Cassader, M., Baldi, S., Ponti, V., Pagano, G., Ferrannini, E., & Rizzetto, M. (2005) · Diabetologia · doi:10.1007/s00125-005-1682-x · Cited by 770
Miyazaki, Y., Mahankali, A., Matsuda, M., Mahankali, S., Hardies, J., Cusi, K., Mandarino, L. J., & DeFronzo, R. A. (2002) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.87.6.8567 · Cited by 726
Gastaldelli, A., Cusi, K., Pettiti, M., Hardies, J., Miyazaki, Y., Berria, R., Buzzigoli, E., Sironi, A. M., Cersosimo, E., Ferrannini, E., et al. (2007) · Gastroenterology · doi:10.1053/j.gastro.2007.04.068 · Cited by 629
Adipose Tissue Quantification by Imaging Methods: A Proposed Classification
Shen, W., Wang, Z., Punyanita, M., Lei, J., Sinav, A., Kral, J. G., Imielinska, C., Ross, R., & Heymsfield, S. B. (2003) · Obesity Research · doi:10.1038/oby.2003.3 · Cited by 509
Wedell-Neergaard, A.-S., Lang Lehrskov, L., Christensen, R. H., Legaard, G. E., Dorph, E., Larsen, M. K., Launbo, N., Fagerlind, S. R., Seide, S. K., Nymand, S., et al. (2019) · Cell Metabolism · doi:10.1016/j.cmet.2018.12.007 · Cited by 403
Metadata
- Authors
- Lancaster, J. L., Ghiatas, A. A., Alyassin, A., Kilcoyne, R. F., Bonora, E., & Defronzo, R. A.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 1991-05
- Volume
- 1
- Issue
- 3
- Pages
- 363-369
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2014392245
- Cited by
- 68
- References
- 3
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.