The DOI matches its Crossref record.
Dynamic gadolinium‐enhanced three‐dimensional abdominal MR arteriography
Abstract
The abdominal aorta and renal, visceral, and iliac arteries were evaluated in 16 patients with three‐dimensional Fourier transform imaging enhanced with gadopentetate dimeglumine. By imaging dynamically during the arterial phase of a 5‐minute injection (0.2 mmol/kg), highly significant (P < .0001) preferential arterial enhancement (signal‐to‐noise ratio ± standard deviation, 10 ± 0.9), with minimal enhancement of the inferior vena cava (5.1 ± 1.4) or background tissues (fat, 4.3 ± 0.7; muscle, 2.4 ± 0.5), was achieved in every patient. In six patients with angiographic and/or surgical correlation, 10 of 10 stenoses and two of two occlusions were correctly identified. No inplane saturation or pulsatility artifact was identified in any of the 16 patients. In conclusion, dynamic imaging during the injection of gadopentetate dimeglumine is a promising technique for evaluation of the abdominal aorta and branch vessels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sato, Y., Nakajima, S., Shiraga, N., Atsumi, H., Yoshida, S., Koller, T., Gerig, G., & Kikinis, R. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(98)80009-1 · Cited by 1,163
Diagnosis of Pulmonary Embolism with Magnetic Resonance Angiography
Meaney, J. F. M., Weg, J. G., Chenevert, T. L., Stafford-Johnson, D., Hamilton, B. H., & Prince, M. R. (1997) · New England Journal of Medicine · doi:10.1056/nejm199705153362004 · Cited by 482
Self-citationMeaney, J. F. M., Prince, M. R., Nostrant, T. T., & Stanley, J. C. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070126 · Cited by 193
Self-citationClinical Safety and Diagnostic Value of the Gadolinium Chelate Gadoterate Meglumine (Gd-DOTA)
Herborn, C. U., Honold, E., Wolf, M., Kemper, J., Kinner, S., Adam, G., & Barkhausen, J. (2007) · Investigative Radiology · doi:10.1097/01.rli.0000248893.01067.e5 · Cited by 126
Carlos, R. C., Stanley, J. C., Stafford-Johnson, D., & Prince, M. R. (2001) · Academic Radiology · doi:10.1016/s1076-6332(03)80767-5 · Cited by 55
Self-citation
Metadata
- Authors
- Prince, M. R., Yucel, E. K., Kaufman, J. A., Harrison, D. C., & Geller, S. C.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 1993-11
- Volume
- 3
- Issue
- 6
- Pages
- 877-881
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W1993508802
- Cited by
- 499
- References
- 0
- FWCI
- 10.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dynamic gadolinium‐enhanced three‐dimensional abdominal MR arteriography. https://app.cochat.ai/papers/10.1002/jmri.1880030614
- The paper
- Prince, M. R., Yucel, E. K., Kaufman, J. A., Harrison, D. C., & Geller, S. C. (1993). Dynamic gadolinium‐enhanced three‐dimensional abdominal MR arteriography. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.1880030614
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.