Surface coil MR imaging of the human brain with an analytic reception profile correction
The DOI matches its Crossref record.
Abstract
An analytic correction method was developed and applied to correct the signal intensity nonuniformity caused by the inhomogeneous reception profile of surface coils used—because of their higher sensitivity—for magnetic resonance imaging of the brain at 1.5 T. The reception profile was analytically modeled by using the Blot–Savart law. The correction considerably improved visual interpretation of the images by modeling and removing the dependence of signal intensity on distance from the coil. The method can be used for single or multiple coils of any planar geometry and in any orientation. Application of this technique allows imaging of the brain with surface coils, yielding increased resolution and signal‐to‐noise ratio, without the penalty of image nonuniformity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A nonparametric method for automatic correction of intensity nonuniformity in MRI data
Sled, J. G., Zijdenbos, A. P., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.668698 · Cited by 4,731
“Nonuniformity due to the frequency response of the receiver and spatial sensitivity of the unloaded RF coils is systematic and can in principle be corrected for by regular calibration or theoretical modeling [6], [7].”
BackgroundAutomated model-based bias field correction of MR images of the brain
Van Leemput, K., Maes, F., Vandermeulen, D., & Suetens, P. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.811268 · Cited by 583
A Review on MR Image Intensity Inhomogeneity Correction
Hou, Z. (2006) · International Journal of Biomedical Imaging · doi:10.1155/ijbi/2006/49515 · Cited by 200
“Hindawi Publishing Corporation International Journal of Biomedical Imaging Volume 2006, Article ID 49515, Pages 1–11 DOI 10.1155/IJBI/2006/49515”
BackgroundInfluentialA review of Methods for Bias Correction in Medical Images
Song, S., Zheng, Y., & He, Y. (2017) · Biomedical Engineering Review · doi:10.18103/bme.v3i1.1550 · Cited by 62
Metadata
- Authors
- Moyher, S. E., Vigneron, D. B., & Nelson, S. J.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 1995-03
- Volume
- 5
- Issue
- 2
- Pages
- 139-144
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2156307400
- Cited by
- 92
- References
- 0
- FWCI
- 6.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Surface coil MR imaging of the human brain with an analytic reception profile correction. https://app.cochat.ai/papers/10.1002/jmri.1880050204
- The paper
- Moyher, S. E., Vigneron, D. B., & Nelson, S. J. (1995). Surface coil MR imaging of the human brain with an analytic reception profile correction. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.1880050204
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).