Local histogram correction of MRI spatially dependent image pixel intensity nonuniformity
The DOI matches its Crossref record.
Abstract
We describe a computationally straightforward post‐hoc statistical method of correcting spatially dependent image pixel intensity nonuniformity based on differences in local tissue intensity distributions. Pixel intensity domains for the various tissues of the composite image are identified and compared to the distributions of local samples. The nonuniformity correction is calculated as the difference of the local sample median from the composite sample median for the tissue class most represented by the sample. The median was chosen to reduce the effect ers on determining the sample statistic and to allow a sample size small enough to accurately estimate the spatial variance of the image intensity nonuniformity. The method was designed for application to two‐dimensional images. Simulations were used to estimate optimal conditions of local histogram kernel size and to test the accuracy of the method under known spatially dependent nonuniformities. The method was also applied to correct a phantom image and cerebral MRIs from 15 healthy subjects. Results show that the method accurately models simulated spatially dependent image intensity differences. Further analysis of clinical MR data showed that the variance of pixel intensities within the cerebral MRI slices and the variance of slice volumes within individuals were significantly reduced after nonuniformity correction. Improved brain‐cerebrospinal fluid segmentation was also obtained. The method significantly reduced the variance of slice volumes within individuals, whether it was applied to the native images or images edited to remove nonbrain tissues. This statistical method was well behaved under the assumptions and the images tested. The general utility of the method was not determined, but conditions for testing the method under a variety of imaging sequences is discussed. We believe that this algorithm can serve as a method for improving MR image segmentation for clinical and research applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A nonparametric method for automatic correction of intensity nonuniformity in MRI data
Sled, J. G., Zijdenbos, A. P., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.668698 · Cited by 4,731
“Chapter 3 Review of intensity non-uniformity correction methods Existing methods for non-uniformity correction can be grouped into three categories: analytic modelling of the non-uniformity [36, 38]; modi ed acquisition protocols that measure non-uniformity [1, 10, 18, 39, 41, 50, 58]; and data-driven postprocessing […”
BackgroundMethodMagnetic Resonance Image Tissue Classification Using a Partial Volume Model
Shattuck, D. W., Sandor-Leahy, S. R., Schaper, K. A., Rottenberg, D. A., & Leahy, R. M. (2001) · NeuroImage · doi:10.1006/nimg.2000.0730 · Cited by 950
Automatic "pipeline" analysis of 3-D MRI data for clinical trials: application to multiple sclerosis
Zijdenbos, A. P., Forghani, R., & Evans, A. C. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.806283 · Cited by 761
DeCarli, C., Massaro, J., Harvey, D., Hald, J., Tullberg, M., Au, R., Beiser, A., D’Agostino, R., & Wolf, P. A. (2005) · Neurobiology of Aging · doi:10.1016/j.neurobiolaging.2004.05.004 · Cited by 680
“Image intensity non-uniformities were then removed from the difference image[22], and the resulting corrected image was modeled as a mixture of two Gaussian probability functions with the segmentation threshold determined at the minimum probability between these two distributions [18,64].”
MethodSelf-citationDeCarli, C., Fletcher, E., Ramey, V., Harvey, D., & Jagust, W. J. (2005) · Stroke · doi:10.1161/01.str.0000150668.58689.f2 · Cited by 496
Self-citation
Metadata
- Authors
- Decarli, C., Murphy, D. G. M., Teichberg, D., Campbell, G., & Sobering, G. S.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 1996-05
- Volume
- 6
- Issue
- 3
- Pages
- 519-528
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2060665323
- Cited by
- 138
- References
- 0
- FWCI
- 5.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Local histogram correction of MRI spatially dependent image pixel intensity nonuniformity. https://app.cochat.ai/papers/10.1002/jmri.1880060316
- The paper
- Decarli, C., Murphy, D. G. M., Teichberg, D., Campbell, G., & Sobering, G. S. (1996). Local histogram correction of MRI spatially dependent image pixel intensity nonuniformity. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.1880060316
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.