The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Magnetically labeled cells can be detected by MR imaging
Abstract
To determine the feasibility of MR imaging of magnetically labeled cells, different cell lines were labeled with monocrystalline iron oxide (MION) particles. Phantoms containing MION labeled cells were then assembled and imaged by MR at 1.5 T using T1‐weighted and T2‐weighted pulse sequences. MION uptake ranged from 8.5 × 10 4 to 2.9 × 10 5 particles/cell for tumor cells (9L and LX1, respectively) to 1.5 × 10 6 to 4.8 × 10 8 particles/cell for “professional phagocytes” (J774 and peritoneal macrophages, respectively). On the T1‐weighted images, cell‐internalized MION appeared hyperintense relative to agar and similar to MION in aqueous solution. On T2‐weighted images, signal intensity varied according to concentration of MION within cells. Cell‐internalized MION caused similar MR signal changes of cells as did free MION; however, at a dose that was an order of magnitude lower, depending on the pulse sequence used. The detectability of MION within cells was approximately 2 ng Fe, which corresponded to 10 5 tumor cells/well or 5 × 10 3 macrophages/well. We conclude that a variety of cells can be efficiently labeled with MION by simple incubation. Intracellular labeling may be used for MR imaging of in vivo cell tracking.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Superparamagnetic iron oxide: pharmacokinetics and toxicity
Weissleder, R., Stark, D., Engelstad, B., Bacon, B., Compton, C., White, D., Jacobs, P., & Lewis, J. (1989) · American Journal of Roentgenology · doi:10.2214/ajr.152.1.167 · Cited by 1,045
Self-citationMonocrystalline iron oxide nanocompounds (MION): Physicochemical properties
Shen, T., Weissleder, R., Papisov, M., Bogdanov, A., & Brady, T. J. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290504 · Cited by 499
Self-citationMacropinosome maturation and fusion with tubular lysosomes in macrophages.
Racoosin, E. L., & Swanson, J. A. (1993) · The Journal of cell biology · doi:10.1083/jcb.121.5.1011 · Cited by 335
Rabinowitz, S., Horstmann, H., Gordon, S., & Griffiths, G. (1992) · The Journal of Cell Biology · doi:10.1083/jcb.116.1.95 · Cited by 271
Dynamic and stable populations of microtubules in cells.
Schulze, E., & Kirschner, M. (1987) · The Journal of cell biology · doi:10.1083/jcb.104.2.277 · Cited by 266
Intracellular labeling of T‐cells with superparamagnetic contrast agents
Yeh, T., Zhang, W., Ildstad, S. T., & Ho, C. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300513 · Cited by 198
New features of microtubule behaviour observed in vivo
Schulze, E., & Kirschner, M. (1988) · Nature · doi:10.1038/334356a0 · Cited by 194
Pratten, M. K., & Lloyd, J. B. (1986) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(86)90020-6 · Cited by 188
Surface functions during mitosis I: Phagocytosis, pinocytosis and mobility of surface-bound ConA
Berlin, R. D., Oliver, J. M., & Walter, R. J. (1978) · Cell · doi:10.1016/0092-8674(78)90002-8 · Cited by 184
Transverse relaxivity of particulate MRI contrast media: From theories to experiments
Muller, R. N., Gillis, P., Moiny, F., & Roch, A. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910220203 · Cited by 171
In Vivo Dynamic MRI Tracking of Rat T‐Cells Labeled with Superparamagnetic Iron‐Oxide Particles
Yeh, T., Zhang, W., Ildstad, S. T., & Ho, C. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330209 · Cited by 170
Specific MR imaging of human lymphocytes by monoclonal antibody‐guided dextran‐magnetite particles
Bulte, J. W. M., Hoekstra, Y., Kamman, R. L., Magin, R. L., WEBB, A. G., Briggs, R. W., Go, K. G., Hulstaert, C. E., Miltenyi, S., THE, T. H., et al. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250115 · Cited by 147
Cellular Uptake and Trafficking of a Prototypical Magnetic Iron Oxide Label In Vitro
Schulze, E., Ferrucci, J. T., Poss, K., LAPOINTE, L., Bogdanova, A., & Weissleder, R. (1995) · Investigative Radiology · doi:10.1097/00004424-199510000-00006 · Cited by 142
Self-citationDelivery of Virus-sized Iron Oxide Particles to Rodent CNS Neurons
Neuwelt, E. A., Weissleder, R., Nilaver, G., Kroll, R. A., Roman-Goldstein, S., Szumowski, J., Pagel, M. A., Jones, R. S., Remsen, L. G., McCormick, C. I., et al. (1994) · Neurosurgery · doi:10.1227/00006123-199404000-00048 · Cited by 135
Self-citationMR imaging of phagocytosis in experimental gliomas.
Zimmer, C., Weissleder, R., Poss, K., Bogdanova, A., Wright, S. C., & Enochs, W. S. (1995) · Radiology · doi:10.1148/radiology.197.2.7480707 · Cited by 121
Self-citationFrequency dependence of MR relaxation times II. Iron oxides
Bulte, J. W. M., Vymazal, J., Brooks, R. A., Pierpaoli, C. M., & Frank, J. A. (1993) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880030414 · Cited by 113
Bogdanov, A. A., Jr., Martin, C., Weissleder, R., & Brady, T. J. (1994) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/0005-2736(94)90350-6 · Cited by 66
Self-citationMajumdar, S., Zoghbi, S., Pope, C. F., et al. (1989) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910090205 · Cited by 66
Product operators and coherence transfer in multiple‐pulse NMR experiments
Shriver, J. W. (1992) · Concepts in Magnetic Resonance · doi:10.1002/cmr.1820040102 · Cited by 62
Mion-ASF: Biokinetics of an MR receptor agent
Schaffer, B. K., Linker, C., Papisov, M. I., Tsai, E., Nossiff, N. D., Shibata, T., Bogdanov, A. A., Jr., Brady, T. J., & Weissleder, R. (1993) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(93)90074-n · Cited by 61
Self-citationNorman, A. B., Thomas, S. R., Pratt, R. G., et al. (1992) · Brain Research · doi:10.1016/0006-8993(92)91135-2 · Cited by 59
Magnetically Labeled Secretin Retains Receptor Affinity to Pancreas Acinar Cells
Shen, T. T., Bogdanov, A. A., Jr., Bogdanova, A., et al. (1996) · Bioconjugate Chemistry · doi:10.1021/bc960003u · Cited by 53
Self-citationNeuwelt, E. A., Barnett, P. A., Hellström, K. E., Hellström, I., McCormick, C. I., & Ramsey, F. L. (1994) · PubMed · Cited by 43
Drug targeting in magnetic resonance imaging.
Weissleder, R., Bogdanov, A. A., Jr., & Papisov, M. I. (1992) · PubMed · Cited by 39
Self-citationQuantitation of MR relaxation effects of iron oxide particles in liver and spleen.
Majumdar, S., Zoghbi, S. S., Pope, C. F., & Gore, J. C. (1988) · Radiology · doi:10.1148/radiology.169.3.3186986 · Cited by 32
Ward, D. M., Perou, C. M., Lloyd, M., & Kaplan, J. (1995) · The Journal of Cell Biology · doi:10.1083/jcb.129.5.1229 · Cited by 24
Cited by
Synthesis and surface engineering of iron oxide nanoparticles for biomedical applications
Gupta, A. K., & Gupta, M. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.10.012 · Cited by 6,771
Molecular imaging in living subjects: seeing fundamental biological processes in a new light
Massoud, T. F., & Gambhir, S. S. (2003) · Genes & Development · doi:10.1101/gad.1047403 · Cited by 2,216
Lewin, M., Carlesso, N., Tung, C.-H., Tang, X.-W., Cory, D., Scadden, D. T., & Weissleder, R. (2000) · Nature Biotechnology · doi:10.1038/74464 · Cited by 1,716
Self-citationFunctionalisation of magnetic nanoparticles for applications in biomedicine
Berry, C. C., & Curtis, A. S. G. (2003) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/36/13/203 · Cited by 1,588
Iron oxide MR contrast agents for molecular and cellular imaging
Bulte, J. W. M., & Kraitchman, D. L. (2004) · NMR in Biomedicine · doi:10.1002/nbm.924 · Cited by 1,500
Metadata
- Authors
- Weissleder, R., Cheng, H., Bogdanova, A., & Bogdanov, A.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 1997-01
- Volume
- 7
- Issue
- 1
- Pages
- 258-263
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W1992295328
- Cited by
- 336
- References
- 26
- FWCI
- 8.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.