Inadequacy of motion correction algorithms in functional MRI: Role of susceptibility‐induced artifacts
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Functional MR (fMR) has been useful in providing insight into the localization and detection of neural cortical activity. However, patient head motion is inevitable over the course of most fMR experiments. Although methods to align the control and activation fMR images may correct for some of this motional error, they will be incomplete in correcting for those that depend on spatial orientation. MR signal amplitude of structures that lie along air‐tissue interfaces, for example, are sensitive to susceptibility errors introduced by their reorientation with respect to the main magnetic field. This analysis, using phantoms, cadaver brain, and volunteers, has shown that this reorientation between control and activation images can create regions of “false activation” that increase in area with rotation. Anatomic regions that are expected to be most affected by these susceptibility‐induced magnetic field homogeneity variations are those adjacent to bone or air, such as the mesial and inferior temporal lobes and the inferior and anterior frontal lobes. Interpretation of “activation” in these areas on fMR studies must be performed with careful consideration of this important source of error.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ogawa, S., Menon, R. S., Tank, D. W., Kim, S. G., Merkle, H., Ellermann, J. M., & Ugurbil, K. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81441-3 · Cited by 1,772
Lai, S., Hopkins, A. L., Haacke, E. M., Li, D., Wasserman, B. A., Buckley, P., Friedman, L., Meltzer, H., Hedera, P., & Friedland, R. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300318 · Cited by 390
Cited by
Power, J. D., Barnes, K. A., Snyder, A. Z., Schlaggar, B. L., & Petersen, S. E. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.10.018 · Cited by 7,429
“It is well established that head motion is undesirable in fMRI studies (Friston et al., 1996; Hutton et al., 2002; Jiang et al., 1995; Johnstone et al., 2006; Oakes et al., 2005; Wu et al., 1997).”
Modeling Geometric Deformations in EPI Time Series
Andersson, J. L. R., Hutton, C., Ashburner, J., Turner, R., & Friston, K. (2001) · NeuroImage · doi:10.1006/nimg.2001.0746 · Cited by 1,011
Siegel, J. S., Power, J. D., Dubis, J. W., Vogel, A. C., Church, J. A., Schlaggar, B. L., & Petersen, S. E. (2014) · Human Brain Mapping · doi:10.1002/hbm.22307 · Cited by 546
What is the best similarity measure for motion correction in fMRI time series?
Freire, L., Roche, A., & Mangin, J.-F. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.1009383 · Cited by 353
Motion Correction Algorithms May Create Spurious Brain Activations in the Absence of Subject Motion
Freire, L., & Mangin, J.-F. (2001) · NeuroImage · doi:10.1006/nimg.2001.0869 · Cited by 308
Metadata
- Authors
- Wu, D. H., Lewin, J. S., & Duerk, J. L.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 1997-03
- Volume
- 7
- Issue
- 2
- Pages
- 365-370
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2015552318
- Cited by
- 80
- References
- 2
- FWCI
- 6.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.