Limits to the accuracy of vessel diameter measurement in MR angiography
Abstract
This work addresses the fundamental limits imposed by the MRI process on the accuracy with which vessel diameters and cross‐sectional areas can be derived from time‐of‐flight (TOF) and phase‐contrast (PC) MR source images. By means of simulations and in vitro experiments, it is demonstrated that, even in the absence of flow‐related artifacts, severe inaccuracies in the determination of diameters or cross‐sectional areas may occur solely because of the physical process of the MR image acquisition. Resolution and intraluminal saturation have strong effects on the vessel appearance and thus on the diameter estimation error. It is shown that low resolution leads to diameter overestimation or even underestimation and that intraluminal saturation causes severe underestimation, even for relatively low flip angles. Velocity and velocity encoding do not have a major influence on lumen appearance in PC images. Accurate diameter estimations can be attained only if lumen diameters constitute at least three pixels for both TOF and PC acquisitions, provided that intraluminal saturation is suppressed or avoided. Additionally, since the constitution of TOF and PC images is dissimilar, lumina should be analyzed differently to obtain accurate diameters and cross‐sectional areas.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Aylward, S. R., & Bullitt, E. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/42.993126 · Cited by 578
IntrA: 3D Intracranial Aneurysm Dataset for Deep Learning
Yang, X., Xia, D., Kin, T., & Igarashi, T. (2020) · 2020 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr42600.2020.00273 · Cited by 99
Metadata
- Authors
- Hoogeveen, R. M., Bakker, C. J. G., & Viergever, M. A.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 1998-11
- Volume
- 8
- Issue
- 6
- Pages
- 1228-1235
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2076805215
- Cited by
- 186
- References
- 0
- FWCI
- 5.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Limits to the accuracy of vessel diameter measurement in MR angiography. https://app.cochat.ai/papers/10.1002/jmri.1880080608
- The paper
- Hoogeveen, R. M., Bakker, C. J. G., & Viergever, M. A. (1998). Limits to the accuracy of vessel diameter measurement in MR angiography. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.1880080608
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.