CoChat

Quantitative high‐resolution magnetic resonance imaging reveals structural implications of renal osteodystrophy on trabecular and cortical bone

Wehrli, Felix W., Leonard, Mary B., Saha, Punam K., Gomberg, Bryon R. · 2004 · Journal of Magnetic Resonance Imaging
Cited by 117

The DOI matches its Crossref record.

Abstract

Purpose: To explore the potential role of micro‐magnetic resonance imaging (μ‐MRI) for quantifying trabecular and cortical bone structural parameters in renal osteodystrophy (ROD), a multifactorial disorder of bone metabolism, traditionally evaluated by bone biopsy. Materials and Methods: Seventeen hemodialysis patients (average PTH level = 502 ± 415 μg/liter) were compared with 17 age‐, gender‐, and body mass index (BMI)‐matched control subjects. The average dialysis duration for the patients was 5.5 years (range = 0.96‐18.2 years). Three‐dimensional (3D) fast large‐angle spin‐echo (FLASE) MR images of the distal tibia (voxel size = 137 × 137 × 410 μm 3) were processed to yield bone volume fraction (BV/TV). From a skeletonized representation of the trabecular bone network, the topology of each bone voxel was determined providing surface and curve voxel densities (SURF and CURV) and the topological erosion index (EI). Further, high‐resolution two‐dimensional (2D) spin‐echo images were collected at the tibial midshaft for measurement of cortical bone cross‐sectional area (CCA), relative CCA expressed as a percentage of total bone area (RCA), and mean cortical thickness (MCT). Results: The data show both RCA and MCT to be lower in the patients (61.2 vs. 69.1%, P = 0.008, and 4.53 vs. 5.19 mm, P = 0.01). BV/TV and SURF were lower, while EI was increased in the patients, although these differences were not quite significant (P = 0.06‐0.09). All of the cortical and trabecular findings are consistent with increased bone fragility. Conclusion: The data suggest that μ‐MRI may have potential to characterize the structural implications of metabolic bone disease, potentially providing a noninvasive tool for the evaluation of therapies for ROD. J. Magn. Reson. Imaging 2004;20:83–89. © 2004 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jmri.20085

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Wehrli, F. W., Leonard, M. B., Saha, P. K., & Gomberg, B. R.
Venue
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Published
2004-06-21
Volume
20
Issue
1
Pages
83-89
ISSN
  • 1053-1807 (ISSN-L)
  • 1522-2586
OpenAlex
W2129042174
Cited by
117
References
0
FWCI
6.20
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.