Quantitative high‐resolution magnetic resonance imaging reveals structural implications of renal osteodystrophy on trabecular and cortical bone
The DOI matches its Crossref record.
Abstract
Purpose: To explore the potential role of micro‐magnetic resonance imaging (μ‐MRI) for quantifying trabecular and cortical bone structural parameters in renal osteodystrophy (ROD), a multifactorial disorder of bone metabolism, traditionally evaluated by bone biopsy. Materials and Methods: Seventeen hemodialysis patients (average PTH level = 502 ± 415 μg/liter) were compared with 17 age‐, gender‐, and body mass index (BMI)‐matched control subjects. The average dialysis duration for the patients was 5.5 years (range = 0.96‐18.2 years). Three‐dimensional (3D) fast large‐angle spin‐echo (FLASE) MR images of the distal tibia (voxel size = 137 × 137 × 410 μm 3) were processed to yield bone volume fraction (BV/TV). From a skeletonized representation of the trabecular bone network, the topology of each bone voxel was determined providing surface and curve voxel densities (SURF and CURV) and the topological erosion index (EI). Further, high‐resolution two‐dimensional (2D) spin‐echo images were collected at the tibial midshaft for measurement of cortical bone cross‐sectional area (CCA), relative CCA expressed as a percentage of total bone area (RCA), and mean cortical thickness (MCT). Results: The data show both RCA and MCT to be lower in the patients (61.2 vs. 69.1%, P = 0.008, and 4.53 vs. 5.19 mm, P = 0.01). BV/TV and SURF were lower, while EI was increased in the patients, although these differences were not quite significant (P = 0.06‐0.09). All of the cortical and trabecular findings are consistent with increased bone fragility. Conclusion: The data suggest that μ‐MRI may have potential to characterize the structural implications of metabolic bone disease, potentially providing a noninvasive tool for the evaluation of therapies for ROD. J. Magn. Reson. Imaging 2004;20:83–89. © 2004 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Boutroy, S., Bouxsein, M. L., Munoz, F., & Delmas, P. D. (2005) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2005-1258 · Cited by 1,192
Osteoporosis Imaging: State of the Art and Advanced Imaging
Link, T. M. (2012) · Radiology · doi:10.1148/radiol.12110462 · Cited by 453
Quantitative MRI of cartilage and bone: degenerative changes in osteoarthritis
Eckstein, F., Burstein, D., & Link, T. M. (2006) · NMR in Biomedicine · doi:10.1002/nbm.1063 · Cited by 343
A review of imaging techniques for systems biology
Kherlopian, A. R., Song, T., Duan, Q., Neimark, M. A., Po, M. J., Gohagan, J. K., & Laine, A. F. (2008) · BMC Systems Biology · doi:10.1186/1752-0509-2-74 · Cited by 310
Chronic kidney disease and bone fracture: A growing concern
Nickolas, T. L., Leonard, M. B., & Shane, E. (2008) · Kidney International · doi:10.1038/ki.2008.264 · Cited by 300
Self-citationOsteoporosis in patients with chronic kidney diseases: A systemic review
Hsu, C.-Y., Chen, L.-R., & Chen, K.-H. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21186846 · Cited by 162
“Peripheral quantitative computed tomography (pQCT), high resolution pQCT (HRpQCT), and micromagnetic resonance imaging (microMRI) are non-invasive 3D imaging techniques that can detect microarchitecture and mineral density of both trabecular and cortical bones [51].”
Qualitative and quantitative ultrashort‐TE MRI of cortical bone
Du, J., & Bydder, G. M. (2013) · NMR in Biomedicine · doi:10.1002/nbm.2906 · Cited by 159
Bone mass and architecture determination: state of the art
Griffith, J. F., & Genant, H. K. (2008) · Best Practice & Research Clinical Endocrinology & Metabolism · doi:10.1016/j.beem.2008.07.003 · Cited by 126
Metadata
- Authors
- Wehrli, F. W., Leonard, M. B., Saha, P. K., & Gomberg, B. R.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2004-06-21
- Volume
- 20
- Issue
- 1
- Pages
- 83-89
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2129042174
- Cited by
- 117
- References
- 0
- FWCI
- 6.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.