Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 234

The DOI matches its Crossref record.

Evaluation of specific absorption rate as a dosimeter of MRI‐related implant heating

Baker, Kenneth B., Tkach, Jean A., Nyenhuis, John A., Phillips, Michael, Shellock, Frank G., Gonzalez‐Martinez, Jorge, Rezai, Ali R.·2004·Journal of Magnetic Resonance Imaging

Abstract

Purpose: To compare the magnetic resonance imaging (MRI)‐related heating per unit of whole body averaged specific absorption rate (SAR) of a conductive implant exposed to two different 1.5‐Tesla/64 MHz MR systems. Materials and Methods: Temperature changes at the electrode contacts of a deep brain stimulation lead were measured using fluoroptic thermometry. The leads were placed in a typical surgical implant configuration within a gel‐filled phantom of the human head and torso. MRI was performed using two different transmit/receive body coils on two different generation 1.5‐Tesla MR systems from the same manufacturer. Temperature changes were normalized to whole body averaged SAR values and compared between the two scanners. Results: Depending on the landmark location, the normalized temperature change for the implant was significantly higher on one MR system compared to the other (P < 0.001). Conclusion: The findings revealed marked differences across two MR systems in the level of radiofrequency (RF)‐induced temperature changes per unit of whole body SAR for a conductive implant. Thus, these data suggest that using SAR to guide MR safety recommendations for neurostimulation systems or other similar implants across different MR systems is unreliable and, therefore, potentially dangerous. Better, more universal, measures are required in order to ensure patient safety. J. Magn. Reson. Imaging 2004;20:315–320. © 2004 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jmri.20103

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 234

Metadata

Authors
Baker, K. B., Tkach, J. A., Nyenhuis, J. A., Phillips, M., Shellock, F. G., Gonzalez‐Martinez, J., & Rezai, A. R.
Venue
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Published
2004-07-16
Volume
20
Issue
2
Pages
315-320
ISSN
  • 1053-1807 (ISSN-L)
  • 1522-2586
OpenAlex
W2127424354
Cited by
234
References
0
FWCI
12.30
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of specific absorption rate as a dosimeter of MRI‐related implant heating. https://app.cochat.ai/papers/10.1002/jmri.20103
The paper
Baker, K. B., Tkach, J. A., Nyenhuis, J. A., Phillips, M., Shellock, F. G., Gonzalez‐Martinez, J., & Rezai, A. R. (2004). Evaluation of specific absorption rate as a dosimeter of MRI‐related implant heating. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.20103

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.