The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Diffusion‐weighted MRI (DWI) in the oncology patient: Value of breathhold DWI compared to unenhanced and gadolinium‐enhanced MRI
Open accessAbstract
Purpose: To evaluate the feasibility and added value of single breathhold diffusion‐weighted (DW) imaging (DWI) in oncology patients undergoing abdominal MRI. Materials and Methods: A total of 169 patients with malignancy underwent abdominal MRI at 1.5T, including T1‐weighted (T1W), T2‐weighted (T2W), and dynamic gadolinium‐enhanced imaging. Axial DWI was performed with a single‐shot spin‐echo (SE) echo‐planar imaging (EPI) sequence using a b‐value of 500 seconds/mm 2. A total of 24 slices were obtained during a 20‐second breathhold. Two observers reviewed the conventional MR images for tumor. Next, the DW images were reviewed for additional tumor not depicted on conventional MR images Results: For the 169 patients, additional tumors were noted on the DW images in 77 (0.46) for observer 1 and 67 (0.40) for observer 2. For observer 1 the additional tumor included lymphadenopathy (47), peritoneal metastases (15), renal (1), liver (12), and osseous (2), while for observer 2 the corresponding values were lymphadenopathy (40), peritoneal (12), renal (1), liver (6), osseous (4), and gastrointestinal (1). The DW images resolved as benign findings noted on the conventional MR images in three patients for observer 1 and four patients for observer 2. The conventional MR exam was entirely normal while the DW images showed tumor in 12 (0.07) patients for observer 1 and 10 (0.06) patients for observer 2. Conclusion: DWI is feasible in a single breathhold and provides additional clinically important information in oncology patients when added to routine abdominal MR sequences. J. Magn. Reson. Imaging 2007. © 2007 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Invited. Ultrafast MR imaging of the abdomen: Echo planar imaging and diffusion‐weighted imaging
Yamashita, Y., Tang, Y., & Takahashi, M. (1998) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880080216 · Cited by 92
Cited by
Diffusion-weighted MR Imaging of the Liver
Taouli, B., & Koh, D.-M. (2010) · Radiology · doi:10.1148/radiol.09090021 · Cited by 810
Parikh, T., Drew, S. J., Lee, V. S., Wong, S., Hecht, E. M., Babb, J. S., & Taouli, B. (2008) · Radiology · doi:10.1148/radiol.2463070432 · Cited by 560
Kwee, T. C., Takahara, T., Ochiai, R., Nievelstein, R. A. J., & Luijten, P. R. (2008) · European Radiology · doi:10.1007/s00330-008-0968-z · Cited by 410
Sala, E., Rockall, A. G., Freeman, S. J., Mitchell, D. G., & Reinhold, C. (2013) · Radiology · doi:10.1148/radiol.12120315 · Cited by 347
Head and Neck Squamous Cell Carcinoma: Value of Diffusion-weighted MR Imaging for Nodal Staging
Vandecaveye, V., De Keyzer, F., Vander Poorten, V., Dirix, P., Verbeken, E., Nuyts, S., & Hermans, R. (2009) · Radiology · doi:10.1148/radiol.2511080128 · Cited by 340
Metadata
- Authors
- Low, R. N., & Gurney, J.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2007-03-02
- Volume
- 25
- Issue
- 4
- Pages
- 848-858
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2090204279
- Cited by
- 182
- References
- 1
- FWCI
- 13.45
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diffusion‐weighted MRI (DWI) in the oncology patient: Value of breathhold DWI compared to unenhanced and gadolinium‐enhanced MRI. https://app.cochat.ai/papers/10.1002/jmri.20864
- The paper
- Low, R. N., & Gurney, J. (2007). Diffusion‐weighted MRI (DWI) in the oncology patient: Value of breathhold DWI compared to unenhanced and gadolinium‐enhanced MRI. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.20864
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.