The DOI matches its Crossref record.
Calculation of MRI‐induced heating of an implanted medical lead wire with an electric field transfer function
Abstract
Purpose: To develop and demonstrate a method to calculate the temperature rise that is induced by the radio frequency (RF) field in MRI at the electrode of an implanted medical lead. Materials and Methods: The electric field near the electrode is calculated by integrating the product of the tangential electric field and a transfer function along the length of the lead. The transfer function is numerically calculated with the method of moments. Transfer functions were calculated at 64 MHz for different lengths of model implants in the form of bare wires and insulated wires with 1 cm of wire exposed at one or both ends. Results: Heating at the electrode depends on the magnitude and the phase distribution of the transfer function and the incident electric field along the length of the lead. For a uniform electric field, the electrode heating is maximized for a lead length of approximately one‐half a wavelength when the lead is terminated open. The heating can be greater for a worst‐case phase distribution of the incident field. Conclusion: The transfer function is proposed as an efficient method to calculate MRI‐induced heating at an electrode of a medical lead. Measured temperature rises of a model implant in a phantom were in good agreement with the rises predicted by the transfer function. The transfer function could be numerically or experimentally determined. J. Magn. Reson. Imaging 2007;26:1278–1285. © 2007 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Potential tissue damage from transcutaneous recharge of neuromodulation implants
Lovik, R. D., Abraham, J. P., & Sparrow, E. M. (2009) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2009.03.010 · Cited by 29
On the model validation of active implantable medical device for MRI safety assessment
Wang, Z., Zheng, J., Wang, Y., Kainz, W., & Chen, J. (2020) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2019.2957766 · Cited by 22
Metadata
- Authors
- Park, S., Kamondetdacha, R., & Nyenhuis, J. A.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2007-10-29
- Volume
- 26
- Issue
- 5
- Pages
- 1278-1285
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W1967011127
- Cited by
- 232
- References
- 0
- FWCI
- 2.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Calculation of MRI‐induced heating of an implanted medical lead wire with an electric field transfer function. https://app.cochat.ai/papers/10.1002/jmri.21159
- The paper
- Park, S., Kamondetdacha, R., & Nyenhuis, J. A. (2007). Calculation of MRI‐induced heating of an implanted medical lead wire with an electric field transfer function. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.21159
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.