CoChat

Dynamic contrast‐enhanced quantitative perfusion measurement of the brain using T1‐weighted MRI at 3T

Open access
Larsson, Henrik B.W., Hansen, Adam E., Berg, Hilde K., Rostrup, Egill, Haraldseth, Olav · 2008 · Journal of Magnetic Resonance Imaging
Cited by 82

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Purpose: To develop a method for the measurement of brain perfusion based on dynamic contrast‐enhanced T1‐weighted MR imaging. Materials and Methods: Dynamic imaging of the first pass of a bolus of a paramagnetic contrast agent was performed using a 3T whole‐body magnet and a T1‐weighted fast field echo sequence. The input function was obtained from the internal carotid artery. An initial T1 measurement was performed in order to convert the MR signal to concentration of the contrast agent. Pixelwise and region of interest (ROI)‐based calculation of cerebral perfusion (CBF) was performed using Tikhonov's procedure of deconvolution. Seven patients with acute optic neuritis and two patients with acute stroke were investigated. Results: The mean perfusion value for ROIs in gray matter was 62 mL/100g/min and 21 mL/100g/min in white matter in patients with acute optic neuritis. The perfusion inside the infarct core was 9 mL/100g/min in one of the stroke patients. The other stroke patient had postischemic hyperperfusion and CBF was 140 mL/100g/min. Conclusion: Absolute values of brain perfusion can be obtained using dynamic contrast‐enhanced MRI. These values correspond to expected values from established PET methods. Furthermore, at 3T pixelwise calculation can be performed, allowing construction of CBF maps. J. Magn. Reson. Imaging 2008;27:754–762. © 2008 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jmri.21328

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 82

Metadata

Authors
Larsson, H. B. W., Hansen, A. E., Berg, H. K., Rostrup, E., & Haraldseth, O.
Venue
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Published
2008-03-27
Volume
27
Issue
4
Pages
754-762
ISSN
  • 1053-1807 (ISSN-L)
  • 1522-2586
OpenAlex
W2045279853
Cited by
82
References
1
FWCI
3.58
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Dynamic contrast‐enhanced quantitative perfusion measurement of the brain using T1‐weighted MRI at 3T. https://app.cochat.ai/papers/10.1002/jmri.21328
The paper
Larsson, H. B. W., Hansen, A. E., Berg, H. K., Rostrup, E., & Haraldseth, O. (2008). Dynamic contrast‐enhanced quantitative perfusion measurement of the brain using T1‐weighted MRI at 3T. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.21328

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.