Apparent diffusion coefficient in pancreatic cancer: Characterization and histopathological correlations
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Purpose: To clarify the components primarily responsible for diffusion abnormalities in pancreatic cancerous tissue. Materials and Methods: Subjects comprised 10 patients with surgically confirmed pancreatic cancer. Diffusion‐weighted (DW) echo‐planar imaging (b value = 0, 500 s/mm 2) was employed to calculate the apparent diffusion coefficient (ADC). ADC values of cancer and noncancerous tissue were calculated. Furthermore, ADC values of the cancer were compared with histopathological results. Results: The mean (±standard deviation) ADC value was significantly lower for tumor (1.27 ± 0.52 × 10−3 mm 2/s) than for noncancerous tissue (1.90 ± 0.41 × 10−3 mm 2/s, P < 0.05). Histopathological examination showed similar proportions of fibrotic area, cellular component, necrosis, and mucin in each case. Regarding the density of fibrosis in cancer, three cases were classified in the loose fibrosis group and the remaining seven cases were classified in the dense fibrosis group. The mean ADC value was significantly higher in the loose fibrosis group (1.88 ± 0.39 × 10−3 mm 2/s) than in the dense fibrosis group (1.01 ± 0.29 × 10−3 mm 2/s, P < 0.05). In quantitative analysis, ADC correlated well with the proportion of collagenous fibers (r = −0.87, P < 0.05). Conclusion: Collagenous fibers may be responsible for diffusion abnormalities in pancreatic cancer. J. Magn. Reson. Imaging 2008;27:1302–1308. © 2008 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fast magnetic resonance diffusion-weighted imaging of acute human stroke
Warach, S., Chien, D., Li, W., Ronthal, M., & Edelman, R. R. (1992) · Neurology · doi:10.1212/wnl.42.9.1717 · Cited by 881
Cited by
Diagnosis and Detection of Pancreatic Cancer
Chu, L. C., Goggins, M. G., & Fishman, E. K. (2017) · The Cancer Journal · doi:10.1097/ppo.0000000000000290 · Cited by 296
Correlations between diffusion-weighted imaging and breast cancer biomarkers
Martincich, L., Deantoni, V., Bertotto, I., Redana, S., Kubatzki, F., Sarotto, I., Rossi, V., Liotti, M., Ponzone, R., Aglietta, M., et al. (2012) · European Radiology · doi:10.1007/s00330-012-2403-8 · Cited by 238
“Indeed, high grade has been associated with lower ADC values in several malignancies [34–36].”
BackgroundKang, K. M., Lee, J. M., Yoon, J. H., Kiefer, B., Han, J. K., & Choi, B. I. (2014) · Radiology · doi:10.1148/radiol.13122712 · Cited by 162
Metadata
- Authors
- Muraoka, N., Uematsu, H., Kimura, H., Imamura, Y., Fujiwara, Y., Murakami, M., Yamaguchi, A., & Itoh, H.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2008-05-26
- Volume
- 27
- Issue
- 6
- Pages
- 1302-1308
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2110796306
- Cited by
- 163
- References
- 1
- FWCI
- 5.97
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.