The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Quantitative analysis of diffusion‐weighted magnetic resonance imaging of the pancreas: Usefulness in characterizing solid pancreatic masses
Open accessAbstract
Purpose: To evaluate whether measurement of apparent diffusion coefficient (ADC) and pure diffusion coefficient (D) can help to characterize solid pancreatic masses. Materials and Methods: Diffusion‐weighted MR imaging was performed in both a patient group (n = 71; pancreatic cancer [n = 47], mass‐forming pancreatitis [n = 13], solid pseudopapillary neoplasm [n = 6], and neuroendocrine tumor [n = 5]) and a normal control group (n = 11) by applying three b‐factors of 0, 500, and 1000 sec/mm 2. ADC 500, ADC 1000, D (ADC using b = 500 and 1000 sec/mm 2), and perfusion fraction (f, 1‐ exp [‐500 sec/mm 2 × (ADC 500 – D)]) of normal pancreas, pancreatic cancer, and mass‐forming pancreatitis were compared using the Kruskal–Wallis test. Receiver operating characteristic (ROC) analysis was performed to evaluate the diagnostic performance and optimal cutoff value of these parameters in differentiating pancreatic cancer from mass‐forming pancreatitis. Results: Normal pancreas had significantly higher mean ADC 500, ADC 1000, and f than either pancreatic cancer (P < 0.001, < 0.001, and 0.004, respectively) or mass‐forming pancreatitis (P < 0.001, < 0.001, and 0.002, respectively). ADC 500, ADC 1000, and D of mass‐forming pancreatitis were significantly lower than those of pancreatic cancer (P = 0.002, 0.004, and 0.014, respectively). Sensitivities and specificities in the diagnosis of pancreatic cancer were 72.3% and 76.9% for ADC 500, 87.2% and 69.2% for ADC 1000, 87.2% and 61.5% for D, and 42.6% and 92.3% for f, respectively. Conclusion: Measurement of ADC and D may be helpful in differentiating pancreatic cancers from mass‐forming pancreatitis. J. Magn. Reson. Imaging 2008;28:928–936. © 2008 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Le Bihan, D., Breton, E., Lallemand, D., Grenier, P., Cabanis, E., & Laval-Jeantet, M. (1986) · Radiology · doi:10.1148/radiology.161.2.3763909 · Cited by 3,912
Cited by
Diffusion-Weighted MRI in the Body: Applications and Challenges in Oncology
Koh, D.-M., & Collins, D. J. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.1403 · Cited by 1,993
Clinical intravoxel incoherent motion and diffusion MR imaging: Past, present, and future
Iima, M., & Le Bihan, D. (2016) · Radiology · doi:10.1148/radiol.2015150244 · Cited by 498
Imaging diagnosis of pancreatic cancer: A state-of-the-art review
Lee, E. S. (2014) · World Journal of Gastroenterology · doi:10.3748/wjg.v20.i24.7864 · Cited by 401
Koh, D.-M., Scurr, E., Collins, D., Kanber, B., Norman, A., Leach, M. O., & Husband, J. E. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.0601 · Cited by 344
Diagnosis and Detection of Pancreatic Cancer
Chu, L. C., Goggins, M. G., & Fishman, E. K. (2017) · The Cancer Journal · doi:10.1097/ppo.0000000000000290 · Cited by 296
Metadata
- Authors
- Lee, S. S., Byun, J. H., Park, B. J., Park, S. H., Kim, N., Park, B., Kim, J. K., & Lee, M.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2008-09-26
- Volume
- 28
- Issue
- 4
- Pages
- 928-936
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2098225477
- Cited by
- 198
- References
- 1
- FWCI
- 10.04
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.