CoChat

Quantitation of brain tissue changes associated with white matter hyperintensities by diffusion‐weighted and magnetization transfer imaging: The LADIS (leukoaraiosis and disability in the elderly) study

Open access
Ropele, Stefan, Seewann, Alexandra, Gouw, Alida A., van der Flier, Wiesje M., Schmidt, Reinhold, Pantoni, Leonardo, Inzitari, Domenico, Erkinjuntti, Timo, Scheltens, Philip, Wahlund, Lars O., Waldemar, Gunhild, Chabriat, Hugues, Ferro, José, Hennerici, Michael, O'Brien, John, Wallin, Anders, Langhorne, Peter, Visser, Marieke C., Barkhof, Frederik, Fazekas, Franz · 2009 · Journal of Magnetic Resonance Imaging
Cited by 39

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Purpose: To explore the value of diffusion‐weighted imaging (DWI) and magnetization transfer imaging (MTI) for the improved detection and quantification of cerebral tissue changes associated with ageing and white matter hyperintensities (WMH). Materials and Methods: DWI (n = 340) and MTI (n = 177) were performed in nine centers of the multinational Leukoaraiosis And DISability (LADIS) study investigating the impact of WMH on 65‐ to 85‐year‐old individuals without prior disability. We assessed the apparent diffusion coefficient (ADC) and magnetization transfer ratio (MTR) of normal appearing brain tissue (NABT) and within WMH and related them to subjects' age and WHM severity according to the Fazekas score. Results: ADC and MTR values showed a significant inter‐site variation, which was stronger for the MTR. After z‐transformation multiple regression analysis revealed WMH severity and age as significant predictors of global ADC and MTR changes. Only lesional ADC, but not MTR was related to WMH severity. Conclusion: ADC and MTR are both sensitive for age and WMH related changes in NABT. The ADC is more sensitive for tissue changes within WMH and appears to be more robust for multicenter settings. J. Magn. Reson. Imaging 2009;29:268–274. © 2009 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jmri.21580

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Ropele, S., Seewann, A., Gouw, A. A., van der Flier, W. M., Schmidt, R., Pantoni, L., Inzitari, D., Erkinjuntti, T., Scheltens, P., Wahlund, L. O., Waldemar, G., Chabriat, H., Ferro, J., Hennerici, M., O'Brien, J., Wallin, A., Langhorne, P., Visser, M. C., Barkhof, F., & Fazekas, F.
Venue
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Published
2009-01-22
Volume
29
Issue
2
Pages
268-274
ISSN
  • 1053-1807 (ISSN-L)
  • 1522-2586
OpenAlex
W2071434330
Cited by
39
References
2
FWCI
2.81
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.