Increased SNR and reduced distortions by averaging multiple gradient echo signals in 3D FLASH imaging of the human brain at 3T
Open accessThe DOI matches its Crossref record.
Abstract
Purpose: To demonstrate how averaging of multiple gradient echoes can improve high‐resolution FLASH (fast low angle shot) magnetic resonance imaging (MRI) of the human brain. Materials and Methods: 3D‐FLASH with multiple bipolar echoes was studied by simulation and in three experiments on human brain at 3T. First, the repetition time (TR) was increased by the square of the flip angle to maintain contrast as derived by theory. Then the number of echoes was increased at constant TR with bandwidths between 110 and 1370 Hz/pixel. Finally, signals of a 12‐echo acquisition train (echo times 4.9–59 msec) were averaged consecutively to study the increase in SNR. Results: At unchanged contrast, the signal increased proportionally with flip angle and sqrt(TR). Increasing the bandwidth improved delineation of the basal cortex and vessels, while most of the loss in the signal‐to‐noise ratio (SNR) was recovered by averaging. Consecutive averaging increased the SNR to reach maximum efficiency at an echo train length corresponding roughly to T. Conclusion: SNR is gained efficiently by acquiring additional echoes and increasing TR (and flip angle accordingly to maintain contrast) until the associated T loss in the averaged signal consumes the sqrt(TR) increase in the steady state. A bandwidth of 350 Hz/pixel or higher and echo trains shorter than T are recommended. J. Magn. Reson. Imaging 2009;29:198–204. © 2008 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Quantitative multi-parameter mapping of R1, PD*, MT, and R2* at 3T: a multi-center validation
Weiskopf, N., Suckling, J., Williams, G., Correia, M. M., Inkster, B., Tait, R., Ooi, C., Bullmore, E. T., & Lutti, A. (2013) · Frontiers in Neuroscience · doi:10.3389/fnins.2013.00095 · Cited by 538
Martin-Bastida, A., Ward, R. J., Newbould, R., Piccini, P., Sharp, D., Kabba, C., Patel, M. C., Spino, M., Connelly, J., Tricta, F., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-01402-2 · Cited by 379
Using high-resolution quantitative mapping of R1 as an index of cortical myelination
Lutti, A., Dick, F., Sereno, M. I., & Weiskopf, N. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.06.005 · Cited by 346
“With this highly efficient approach, the acquisition parameters are optimized to maximize SNR and minimize bias (Helms and Dechent, 2009; Helms et al., 2011).”
Draganski, B., Ashburner, J., Hutton, C., Kherif, F., Frackowiak, R. S. J., Helms, G., & Weiskopf, N. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.01.052 · Cited by 294
Self-citationCallaghan, M. F., Freund, P., Draganski, B., Anderson, E., Cappelletti, M., Chowdhury, R., Diedrichsen, J., FitzGerald, T. H. B., Smittenaar, P., Helms, G., et al. (2014) · Neurobiology of Aging · doi:10.1016/j.neurobiolaging.2014.02.008 · Cited by 292
“The setof echoes for eachacquired weighting were then averaged to increase the signal-to-noise ratio (Helms and Dechent, 2009).”
BackgroundMethodSelf-citationCarey, D., Krishnan, S., Callaghan, M. F., Sereno, M. I., & Dick, F. (2017) · Cerebral Cortex · doi:10.1093/cercor/bhw393 · Cited by 63
Kim, E., Di Censo, D., Baraldo, M., Simmons, C., Rosa, I., Randall, K., Ballard, C., Dickie, B. R., Williams, S. C. R., Killick, R., et al. (2021) · Scientific Reports · doi:10.1038/s41598-021-91899-5 · Cited by 15
Metadata
- Authors
- Helms, G., & Dechent, P.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2008-12-18
- Volume
- 29
- Issue
- 1
- Pages
- 198-204
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W1970083490
- Cited by
- 97
- References
- 0
- FWCI
- 3.35
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.