The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Free‐breathing diffusion‐weighted imaging for the assessment of inflammatory activity in Crohn's disease
Open accessAbstract
Purpose: To investigate the application of free‐breathing diffusion‐weighted MR imaging (DWI) to the assessment of disease activity in Crohn's disease. Materials and Methods: Thirty‐one patients with Crohn's disease were investigated using free‐breathing DWI without special patient preparation or IV or intraluminal contrast agent. The bowel was divided into seven segments, and disease activity was assessed visually on DWI. For quantitative analysis, the apparent diffusion coefficient (ADC) was measured in each segment. The findings of a conventional barium study or surgery were regarded as the gold standard for evaluating the diagnostic ability of DWI to assess disease activity. Results: Upon visual assessment, the sensitivity, specificity, and accuracy for the detection of disease‐active segments were 86.0, 81.4, and 82.4%, respectively. In the quantitative assessment, the ADC value in the disease‐active area was lower than that in disease‐inactive area in small and large bowels (1.61 ± 0.44×10−3 mm 2/s versus 2.56 ± 0.51 × 10−3 mm 2/s in small bowel and 1.52 ± 0.43 × 10−3 mm 2/s versus 2.31 ± 0.59 × 10−3 mm 2/s in large bowel, respectively, P<0.001). Conclusion: Free‐breathing DWI is useful in the assessment of Crohn's disease. The accuracy of DWI is high in evaluating disease activity, especially in the small bowel, and the ADC may facilitate quantitative analysis of disease activity. J. Magn. Reson. Imaging 2009;29:880–886. © 2009 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Targan, S. R., Hanauer, S. B., van Deventer, S. J. H., Mayer, L., Present, D. H., Braakman, T., DeWoody, K. L., Schaible, T. F., & Rutgeerts, P. J. (1997) · New England Journal of Medicine · doi:10.1056/nejm199710093371502 · Cited by 3,135
Cited by
Oussalah, A., Laurent, V., Bruot, O., Bressenot, A., Bigard, M.-A., Régent, D., & Peyrin-Biroulet, L. (2010) · Gut · doi:10.1136/gut.2009.197665 · Cited by 263
Metadata
- Authors
- Kiryu, S., Dodanuki, K., Takao, H., Watanabe, M., Inoue, Y., Takazoe, M., Sahara, R., Unuma, K., & Ohtomo, K.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2009-03-20
- Volume
- 29
- Issue
- 4
- Pages
- 880-886
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2166109474
- Cited by
- 185
- References
- 1
- FWCI
- 6.42
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Free‐breathing diffusion‐weighted imaging for the assessment of inflammatory activity in Crohn's disease. https://app.cochat.ai/papers/10.1002/jmri.21725
- The paper
- Kiryu, S., Dodanuki, K., Takao, H., Watanabe, M., Inoue, Y., Takazoe, M., Sahara, R., Unuma, K., & Ohtomo, K. (2009). Free‐breathing diffusion‐weighted imaging for the assessment of inflammatory activity in Crohn's disease. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.21725
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.