The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Differential diagnosis of mammographically and clinically occult breast lesions on diffusion‐weighted MRI
Open accessAbstract
Purpose: To investigate the diagnostic performance of diffusion‐weighted imaging (DWI) for mammographically and clinically occult breast lesions. Materials and Methods: The study included 91 women with 118 breast lesions (91 benign, 12 ductal carcinoma in situ [DCIS], 15 invasive carcinoma) initially detected on dynamic contrast‐enhanced magnetic resonance imaging (DCE‐MRI) and assigned BI‐RADS category 3, 4, or 5. DWI was acquired with b = 0 and 600 s/mm 2. Lesion visibility was assessed on DWI. Apparent diffusion coefficient (ADC) values were compared between malignancies, benign lesions, and normal (no abnormal enhancement on DCE‐MRI) breast tissue, and the diagnostic performance of DWI was assessed based on ADC thresholding. Results: Twenty‐four of 27 (89%) malignant and 74/91 (81%) benign lesions were hyperintense on the b = 600 s/mm 2 diffusion‐weighted images. Both DCIS (1.33 ± 0.19 × 10−3 mm 2/s) and invasive carcinomas (1.30 ± 0.27 × 10−3 mm 2/s) were lower in ADC than benign lesions (1.71 ± 0.43 × 10−3 mm 2/s;P< 0.001), and each lesion type was lower in ADC than normal tissue (1.90 ± 0.38 × 10−3 mm 2/s,P≤ 0.001). Receiver operating curve (ROC) analysis showed an area under the curve (AUC) of 0.77, and sensitivity = 96%, specificity = 55%, positive predictive value (PPV) = 39%, and negative predictive value (NPV) = 98% for an ADC threshold of 1.60 × 10−3 mm 2/s. Conclusion: Many mammographically and clinically occult breast carcinomas were visibly hyperintense on diffusion‐weighted images, and ADC enabled differentiation from benign lesions. Further studies evaluating DWI while blinded to DCE‐MRI are necessary to assess the potential of DWI as a noncontrast breast screening technique. J. Magn. Reson. Imaging 2010;1:562–570. © 2010 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Parikh, T., Drew, S. J., Lee, V. S., Wong, S., Hecht, E. M., Babb, J. S., & Taouli, B. (2008) · Radiology · doi:10.1148/radiol.2463070432 · Cited by 560
Cited by
Diffusion-weighted breast MRI: Clinical applications and emerging techniques
Partridge, S. C., Nissan, N., Rahbar, H., Kitsch, A. E., & Sigmund, E. E. (2017) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25479 · Cited by 340
Self-citation
Metadata
- Authors
- Partridge, S. C., DeMartini, W. B., Kurland, B. F., Eby, P. R., White, S. W., & Lehman, C. D.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2010-02-25
- Volume
- 31
- Issue
- 3
- Pages
- 562-570
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W1981900795
- Cited by
- 173
- References
- 1
- FWCI
- 11.09
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Differential diagnosis of mammographically and clinically occult breast lesions on diffusion‐weighted MRI. https://app.cochat.ai/papers/10.1002/jmri.22078
- The paper
- Partridge, S. C., DeMartini, W. B., Kurland, B. F., Eby, P. R., White, S. W., & Lehman, C. D. (2010). Differential diagnosis of mammographically and clinically occult breast lesions on diffusion‐weighted MRI. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.22078
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.