Ground truth hardware phantoms for validation of diffusion‐weighted MRI applications
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Purpose: To quantitatively validate diffusion‐weighted MRI (DW‐MRI) applications, a hardware phantom containing crossing fibers at a sub‐voxel level is presented. It is suitable for validation of a large spectrum of DW‐MRI applications from acquisition to fiber tracking, which is an important recurrent issue in the field. Materials and Methods: Phantom properties were optimized to resemble properties of human white matter in terms of anisotropy, fractional anisotropy, and T2. Sub‐voxel crossings were constructed at angles of 30, 50, and 65 degrees, by wrapping polyester fibers, with a diameter close to axon diameter, into heat shrink tubes. We show our phantoms are suitable for the acquisition of DW‐MRI data using a clinical protocol. Results: The phantoms can be used to succesfully estimate both the diffusion tensor and non‐Gaussian diffusion models, and perform streamline fiber tracking. DOT (Diffusion Orientation Transform) and q‐ball reconstruction of the diffusion profiles acquired at b = 3000 s/mm 2 and 132 diffusion directions reveal multimodal diffusion profiles in voxels containing crossing yarn strands. Conclusion: The highly purpose adaptable phantoms provide a DW‐MRI validation platform: applications include optimisation of acquisition schemes, validation of non‐Gaussian diffusion models, comparison and validation of fiber tracking algorithms, and quality control in multi‐center DWI studies. J. Magn. Reson. Imaging 2010;32:482–488. © 2010 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The basis of anisotropic water diffusion in the nervous system—A technical review.
Beaulieu, C. (2002) · NMR in Biomedicine · doi:10.1002/nbm.782 · Cited by 4,628
Tuch, D. S. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20279 · Cited by 1,880
Campbell, J. S. W., Siddiqi, K., Rymar, V. V., Sadikot, A. F., & Pike, G. B. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.05.014 · Cited by 177 · cited 1×
“Vegetables with fibrous structures such as asparagus have been used (2) as well as prepared rat spinal cords (3) or other animal nerve structures, i.”
Background
Cited by
Tractography-based connectomes are dominated by false-positive connections
Maier-Hein, K. H., Neher, P., Houde, J.-C., Côté, M.-A., Garyfallidis, E., Zhong, J., Chamberland, M., Yeh, F.-C., Lin, Y.-C., Ji, Q., et al. (2016) · doi:10.1101/084137 · Cited by 1,376
Quantitative evaluation of 10 tractography algorithms on a realistic diffusion MR phantom
Fillard, P., Descoteaux, M., Goh, A., Gouttard, S., Jeurissen, B., Malcolm, J., Ramirez-Manzanares, A., Reisert, M., Sakaie, K., Tensaouti, F., et al. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.01.032 · Cited by 418
Tractometer: Towards validation of tractography pipelines
Côté, M.-A., Girard, G., Boré, A., Garyfallidis, E., Houde, J.-C., & Descoteaux, M. (2013) · Medical Image Analysis · doi:10.1016/j.media.2013.03.009 · Cited by 228
“, 2011), where synthetic phantom data (Perrin et al., 2005; Fieremans et al., 2008; Pullens et al., 2010; Bach et al., 2011; Moussavi-Biugui et al., 2011), histological data (Leergaard et al.”
BackgroundQuantitative Comparison of Reconstruction Methods for Intra-Voxel Fiber Recovery From Diffusion MRI
Daducci, A., Canales-Rodriguez, E. J., Descoteaux, M., Garyfallidis, E., Gur, Y., Lin, Y.-C., Mani, M., Merlet, S., Paquette, M., Ramirez-Manzanares, A., et al. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2285500 · Cited by 172
Quantitative magnetic resonance imaging phantoms: A review and the need for a system phantom
Keenan, K. E., Ainslie, M., Barker, A. J., Boss, M. A., Cecil, K. M., Charles, C., Chenevert, T. L., Clarke, L., Evelhoch, J. L., Finn, P., et al. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26982 · Cited by 170
Metadata
- Authors
- Pullens, P., Roebroeck, A., & Goebel, R.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2010-07-22
- Volume
- 32
- Issue
- 2
- Pages
- 482-488
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2077880784
- Cited by
- 71
- References
- 3
- FWCI
- 4.10
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ground truth hardware phantoms for validation of diffusion‐weighted MRI applications. https://app.cochat.ai/papers/10.1002/jmri.22243
- The paper
- Pullens, P., Roebroeck, A., & Goebel, R. (2010). Ground truth hardware phantoms for validation of diffusion‐weighted MRI applications. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.22243
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.