The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Test–retest reliability of arterial spin labeling with common labeling strategies
Open accessAbstract
Purpose: To compare the test–retest reproducibility of three variants of arterial spin labeling (ASL): pseudo‐continuous (pCASL), pulsed (PASL) and continuous (CASL). Materials and Methods: Twelve healthy subjects were scanned on a 3.0T scanner with PASL, CASL, and pCASL. Scans were repeated within‐session, after 1 hour, and after 1 week to assess reproducibility at different scan intervals. Results: Comparison of within‐subject coefficients of variation (wsCV) demonstrated high within‐session reproducibility (ie, low wsCV) for CASL‐based methods (gray matter [GM] wsCV for pCASL: 3.5% ± 0.02%, CASL: 4.1% ± 0.07%) compared to PASL (wsCV: 7.5% ± 0.06%), due to the higher signal‐to‐noise ratio (SNR) associated with continuous labeling, evident in the 20% gain in temporal SNR and 58% gain in raw SNR for pCASL relative to PASL. At the 1‐week scan interval, comparable reproducibility between PASL (GM wsCV 9.2% ± 0.12%) and pCASL (GM wsCV 8.5% ± 0.14%) was observed, indicating the dominance of physiological fluctuations. Conclusion: Although all three approaches are capable of measuring cerebral blood flow within a few minutes of scanning, the high precision and SNR of pCASL, with its insensitivity to vessel geometry, make it an appealing method for future ASL application studies. J. Magn. Reson. Imaging 2011;33:940–949. © 2011 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Cited by
Alsop, D. C., Detre, J. A., Golay, X., Günther, M., Hendrikse, J., Hernandez‐Garcia, L., Lu, H., MacIntosh, B. J., Parkes, L. M., Smits, M., et al. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25197 · Cited by 2,206
Self-citationKoenig, A. M., Mechanic-Hamilton, D., Xie, S. X., Combs, M. F., Cappola, A. R., Xie, L., Detre, J. A., Wolk, D. A., & Arnold, S. E. (2017) · Alzheimer Disease & Associated Disorders · doi:10.1097/wad.0000000000000202 · Cited by 350
Self-citationApplications of arterial spin labeled MRI in the brain
Detre, J. A., Rao, H., Wang, D. J. J., Chen, Y. F., & Wang, Z. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23581 · Cited by 326
Self-citationCerebrovascular reactivity (CVR) MRI with CO2 challenge: A technical review
Liu, P., De Vis, J. B., & Lu, H. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2018.03.047 · Cited by 278
Voxel-level comparison of arterial spin-labeled perfusion MRI and FDG-PET in Alzheimer disease
Chen, Y., Wolk, D. A., Reddin, J. S., Korczykowski, M., Martinez, P. M., Musiek, E. S., Newberg, A. B., Julin, P., Arnold, S. E., Greenberg, J. H., et al. (2011) · Neurology · doi:10.1212/wnl.0b013e31823a0ef7 · Cited by 259
Self-citation
Metadata
- Authors
- Chen, Y., Wang, D. J. J., & Detre, J. A.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2011-03-29
- Volume
- 33
- Issue
- 4
- Pages
- 940-949
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2120338775
- Cited by
- 238
- References
- 1
- FWCI
- 15.17
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Test–retest reliability of arterial spin labeling with common labeling strategies. https://app.cochat.ai/papers/10.1002/jmri.22345
- The paper
- Chen, Y., Wang, D. J. J., & Detre, J. A. (2011). Test–retest reliability of arterial spin labeling with common labeling strategies. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.22345
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.