The DOI matches its Crossref record.
Non‐contrast enhanced MR angiography: Physical principles
Open accessAbstract
Noncontrast‐enhanced magnetic resonance angiography (NCE‐MRA) methods have been demonstrated in anatomies throughout the body. Previously established NCE‐MRA techniques suffered from long scan times or low sensitivity. Advances in hardware and software have made NCE‐MRA scan times clinically feasible. Recent concerns over the safety of gadolinium‐based contrast material combined with the expense of the material and its administration have generated a demand for NCE‐MRA. In response, several new NCE‐MRA methods have been developed. The physical mechanisms underlying five general classes of NCE‐MRA methods (inflow effect, flow‐dependency on cardiac phase, flow‐encoding, spin labeling, and relaxation) are explained. The original techniques of time‐of‐flight (TOF) and phase contrast MRA (PC‐MRA) are briefly introduced. New developments in NCE‐MRA, including hybrid of opposite‐contrast (HOP‐MRA), four dimensional PC‐MRA (4D Flow), cardiac‐gated 3D fast‐spin‐echo, flow‐sensitive dephasing (FSD), arterial spin labeling (ASL), and balanced steady‐state free‐precession (bSSFP) are highlighted. The primary applications, advantages, and limitations of established and emerging NCE‐MRA techniques are discussed. J. Magn. Reson. Imaging 2012;36:286–304. © 2012 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Chemistry of MRI Contrast Agents: Current Challenges and New Frontiers
Wahsner, J., Gale, E. M., Rodríguez-Rodríguez, A., & Caravan, P. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00363 · Cited by 1,603
Mi, P., Kokuryo, D., Cabral, H., Wu, H., Terada, Y., Saga, T., Aoki, I., Nishiyama, N., & Kataoka, K. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.72 · Cited by 512
Nanoparticles for Imaging: top or Flop?
Kiessling, F., Mertens, M. E., Grimm, J., & Lammers, T. (2014) · Radiology · doi:10.1148/radiol.14131520 · Cited by 228
Metadata
- Authors
- Wheaton, A. J., & Miyazaki, M.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2012-07-17
- Volume
- 36
- Issue
- 2
- Pages
- 286-304
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W1970550688
- Cited by
- 168
- References
- 0
- FWCI
- 8.90
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Non‐contrast enhanced MR angiography: Physical principles. https://app.cochat.ai/papers/10.1002/jmri.23641
- The paper
- Wheaton, A. J., & Miyazaki, M. (2012). Non‐contrast enhanced MR angiography: Physical principles. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.23641
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.