Automatic intra‐subject registration‐based segmentation of abdominal fat from water–fat MRI
Open accessThe DOI matches its Crossref record.
Abstract
Purpose: To develop an automatic registration‐based segmentation algorithm for measuring abdominal adipose tissue depot volumes and organ fat fraction content from three‐dimensional (3D) water–fat MRI data, and to evaluate its performance against manual segmentation. Materials and Methods: Data were obtained from 11 subjects at two time points with intermediate repositioning, and from four subjects before and after a meal with repositioning. Imaging was performed on a 3 Tesla MRI, using the IDEAL chemical‐shift water–fat pulse sequence. Adipose tissue (subcutaneous—SAT, visceral—VAT) and organs (liver, pancreas) were manually segmented twice for each scan by a single trained observer. Automated segmentations of each subject's second scan were generated using a nonrigid volume registration algorithm for water–fat MRI images that used a b‐spline basis for deformation and minimized image dissimilarity after the deformation. Manual and automated segmentations were compared using Dice coefficients and linear regression of SAT and VAT volumes, organ volumes, and hepatic and pancreatic fat fractions (HFF, PFF). Results: Manual segmentations from the 11 repositioned subjects exhibited strong repeatability and set performance benchmarks. The average Dice coefficients were 0.9747 (SAT), 0.9424 (VAT), 0.9404 (liver), and 0.8205 (pancreas); the linear correlation coefficients were 0.9994 (SAT volume), 0.9974 (VAT volume), 0.9885 (liver volume), 0.9782 (pancreas volume), 0.9996 (HFF), and 0.9660 (PFF). When comparing manual and automated segmentations, the average Dice coefficients were 0.9043 (SAT volume), 0.8235 (VAT), 0.8942 (liver), and 0.7168 (pancreas); the linear correlation coefficients were 0.9493 (SAT volume), 0.9982 (VAT volume), 0.9326 (liver volume), 0.8876 (pancreas volume), 0.9972 (HFF), and 0.8617 (PFF). In the four pre‐ and post‐prandial subjects, the Dice coefficients were 0.9024 (SAT), 0.7781 (VAT), 0.8799 (liver), and 0.5179 (pancreas); the linear correlation coefficients were 0.9889, 0.9902 (SAT, and VAT volume), 0.9523 (liver volume), 0.8760 (pancreas volume), 0.9991 (HFF), and 0.6338 (PFF). Conclusion: Automated intra‐subject registration‐based segmentation is potentially suitable for the quantification of abdominal and organ fat and achieves comparable quantitative endpoints with respect to manual segmentation. J. Magn. Reson. Imaging 2013;37:423–430. © 2012 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Reproducibility and repeatability of MRI‐based body composition analysis
Borga, M., Ahlgren, A., Romu, T., Widholm, P., Dahlqvist Leinhard, O., & West, J. (2020) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28360 · Cited by 94
Segmentation and quantification of adipose tissue by magnetic resonance imaging
Hu, H. H., Chen, J., & Shen, W. (2016) · Magnetic Resonance Materials in Physics, Biology and Medicine · doi:10.1007/s10334-015-0498-z · Cited by 90
Agarwal, S. M., Panda, R., Costa-Dookhan, K. A., MacKenzie, N. E., Treen, Q. C., Caravaggio, F., Hashim, E., Leung, G., Kirpalani, A., Matheson, K., et al. (2021) · Translational Psychiatry · doi:10.1038/s41398-021-01338-2 · Cited by 41
Validation of a free software for unsupervised assessment of abdominal fat in MRI
Maddalo, M., Zorza, I., Zubani, S., Nocivelli, G., Calandra, G., Soldini, P., Mascaro, L., & Maroldi, R. (2017) · Physica Medica · doi:10.1016/j.ejmp.2017.04.002 · Cited by 17
Metadata
- Authors
- Joshi, A. A., Hu, H. H., Leahy, R. M., Goran, M. I., & Nayak, K. S.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2012-09-25
- Volume
- 37
- Issue
- 2
- Pages
- 423-430
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2080068681
- Cited by
- 41
- References
- 0
- FWCI
- 4.92
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.