CoChat

Stimulated echo diffusion tensor imaging and SPAIR T2‐weighted imaging in chronic exertional compartment syndrome of the lower leg muscles

Open access
Sigmund, Eric E., Sui, Dabang, Ukpebor, Obehi, Baete, Steven, Fieremans, Els, Babb, James S., Mechlin, Michael, Liu, Kecheng, Kwon, Jane, Mcgorty, KellyAnne, Hodnett, Philip A., Bencardino, Jenny · 2013 · Journal of Magnetic Resonance Imaging
Cited by 50

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Purpose: To evaluate the performance of diffusion tensor imaging (DTI) in the evaluation of chronic exertional compartment syndrome (CECS) as compared to T 2‐weighted (T2w) imaging. Materials and Methods: Using an Institutional Review Board (IRB)‐approved, Health Insurance Portability and Accountability Act (HIPAA)‐compliant protocol, spectral adiabatic inversion recovery (SPAIR) T2w imaging and stimulated echo DTI were applied to eight healthy volunteers and 14 suspected CECS patients before and after exertion. Longitudinal and transverse diffusion eigenvalues, mean diffusivity (MD), and fractional anisotropy (FA) were measured in seven calf muscle compartments, which in patients were classified by their response on T2w: normal (<20% change), and CECS (>20% change). Mixed model analysis of variance compared subject groups and compartments in terms of response factors (post/pre‐exercise ratios) of DTI parameters. Results: All diffusivities significantly increased (P < 0.0001) and FA decreased (P = 0.0014) with exercise. Longitudinal diffusion responses were significantly smaller than transversal diffusion responses (P < 0.0001). Nineteen of 98 patient compartments were classified as CECS on T2w. MD increased by 3.8 ± 3.4% (volunteer), 7.4 ± 4.2% (normal), and 9.1 ± 7.0% (CECS) with exercise. Conclusion: DTI shows promise as an ancillary imaging method in the diagnosis and understanding of the pathophysiology in CECS. Future studies may explore its utility in predicting response to treatment. J. Magn. Reson. Imaging 2013;38:1073–1082. © 2013 Wiley Periodicals, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jmri.24060

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 50

Metadata

Authors
Sigmund, E. E., Sui, D., Ukpebor, O., Baete, S., Fieremans, E., Babb, J. S., Mechlin, M., Liu, K., Kwon, J., Mcgorty, K., Hodnett, P. A., & Bencardino, J.
Venue
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Published
2013-02-25
Volume
38
Issue
5
Pages
1073-1082
ISSN
  • 1053-1807 (ISSN-L)
  • 1522-2586
OpenAlex
W1514698327
Cited by
50
References
1
FWCI
6.59
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Stimulated echo diffusion tensor imaging and SPAIR T2‐weighted imaging in chronic exertional compartment syndrome of the lower leg muscles. https://app.cochat.ai/papers/10.1002/jmri.24060
The paper
Sigmund, E. E., Sui, D., Ukpebor, O., Baete, S., Fieremans, E., Babb, J. S., Mechlin, M., Liu, K., Kwon, J., Mcgorty, K., Hodnett, P. A., & Bencardino, J. (2013). Stimulated echo diffusion tensor imaging and SPAIR T2‐weighted imaging in chronic exertional compartment syndrome of the lower leg muscles. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.24060

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.