Water–fat MRI for assessing changes in bone marrow composition due to radiation and chemotherapy in gynecologic cancer patients
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Purpose: To assess the feasibility of using fat‐fraction imaging for measuring marrow composition changes over large regions in patients undergoing cancer therapy. Materials and Methods: Thirteen women with gynecologic malignancies who were to receive radiation and/or chemotherapy were recruited for this study. Subjects were imaged on a 3T magnetic resonance (MR) scanner at baseline (after surgery but before radiation or chemotherapy), 6 months, and 12 months after treatment. Water–fat imaging was used to generate high‐resolution, 3D signal fat fraction (sFF) maps extending from mid‐femur to L3. Treatment changes were assessed by measuring marrow sFF in the L4 vertebra, femoral necks, and control tissues. Results: Pretreatment and 6‐month scans were compared in nine women. sFF increased significantly in both the L4 vertebral marrow (P = 0.04) and the femoral necks (P = 0.03), while no significant change was observed in control regions. Qualitatively, chemotherapy changes were more uniform in space, whereas the radiation‐induced changes were largest in marrow regions inside and close to the target radiation field. Conclusion: Water–fat MRI is sensitive to changes in red/yellow marrow composition, and can be used for quantitative and qualitative assessment of treatment‐induced marrow damage. J. Magn. Reson. Imaging 2013;38:1578–1584. © 2013 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
TAZ, a Transcriptional Modulator of Mesenchymal Stem Cell Differentiation
Hong, J.-H., Hwang, E. S., McManus, M. T., Amsterdam, A., Tian, Y., Kalmukova, R., Mueller, E., Benjamin, T., Spiegelman, B. M., Sharp, P. A., et al. (2005) · Science · doi:10.1126/science.1110955 · Cited by 1,009 · cited 1×
“In immediate clinical applications, there are several therapeutic interventions, such as antiresorptive agents and modulator of mesenchymal stem cell differentiation that can potentially reduce marrow adiposis (25,26).”
Background
Cited by
Quantitative MRI and spectroscopy of bone marrow
Karampinos, D. C., Ruschke, S., Dieckmeyer, M., Diefenbach, M., Franz, D., Gersing, A. S., Krug, R., & Baum, T. (2018) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25769 · Cited by 285
Clinical implications of bone marrow adiposity
Veldhuis‐Vlug, A. G., & Rosen, C. J. (2018) · Journal of Internal Medicine · doi:10.1111/joim.12718 · Cited by 242
Ali, D., Tencerova, M., Figeac, F., Kassem, M., & Jafari, A. (2022) · Frontiers in Endocrinology · doi:10.3389/fendo.2022.981487 · Cited by 122
MRI in the assessment of adipose tissues and muscle composition: how to use it
Huber, F. A., Del Grande, F., Rizzo, S., Guglielmi, G., & Guggenberger, R. (2020) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims.2020.02.06 · Cited by 102
The implications of bone marrow adipose tissue on inflammaging
Aaron, N., Costa, S., Rosen, C. J., & Qiang, L. (2022) · Frontiers in Endocrinology · doi:10.3389/fendo.2022.853765 · Cited by 74
Metadata
- Authors
- Bolan, P. J., Arentsen, L., Sueblinvong, T., Zhang, Y., Moeller, S., Carter, J. S., Downs, L. S., Ghebre, R., Yee, D., Froelich, J., & Hui, S.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2013-02-28
- Volume
- 38
- Issue
- 6
- Pages
- 1578-1584
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W1896068987
- Cited by
- 101
- References
- 1
- FWCI
- 5.47
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.