CoChat

Radiomic features for prostate cancer detection on MRI differ between the transition and peripheral zones: Preliminary findings from a multi‐institutional study

Open access
Ginsburg, Shoshana B., Algohary, Ahmad, Pahwa, Shivani, Gulani, Vikas, Ponsky, Lee, Aronen, Hannu J., Boström, Peter J., Böhm, Maret, Haynes, Anne‐Maree, Brenner, Phillip, Delprado, Warick, Thompson, James, Pulbrock, Marley, Taimen, Pekka, Villani, Robert, Stricker, Phillip, Rastinehad, Ardeshir R., Jambor, Ivan, Madabhushi, Anant · 2017 · Journal of Magnetic Resonance Imaging
Cited by 143

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

PURPOSE: To evaluate in a multi-institutional study whether radiomic features useful for prostate cancer (PCa) detection from 3 Tesla (T) multi-parametric MRI (mpMRI) in the transition zone (TZ) differ from those in the peripheral zone (PZ). MATERIALS AND METHODS: 3T mpMRI, including T2-weighted (T2w), apparent diffusion coefficient (ADC) maps, and dynamic contrast-enhanced MRI (DCE-MRI), were retrospectively obtained from 80 patients at three institutions. This study was approved by the institutional review board of each participating institution. First-order statistical, co-occurrence, and wavelet features were extracted from T2w MRI and ADC maps, and contrast kinetic features were extracted from DCE-MRI. Feature selection was performed to identify 10 features for PCa detection in the TZ and PZ, respectively. Two logistic regression classifiers used these features to detect PCa and were evaluated by area under the receiver-operating characteristic curve (AUC). Classifier performance was compared with a zone-ignorant classifier. RESULTS: Radiomic features that were identified as useful for PCa detection differed between TZ and PZ. When classification was performed on a per-voxel basis, a PZ-specific classifier detected PZ tumors on an independent test set with significantly higher accuracy (AUC = 0.61-0.71) than a zone-ignorant classifier trained to detect cancer throughout the entire prostate (P < 0.05). When classifiers were evaluated on MRI data from multiple institutions, statistically similar AUC values (P > 0.14) were obtained for all institutions. CONCLUSION: A zone-aware classifier significantly improves the accuracy of cancer detection in the PZ. LEVEL OF EVIDENCE: 3 Technical Efficacy: Stage 2 J. MAGN. RESON. IMAGING 2017;46:184-193.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jmri.25562

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 143

Metadata

Authors
Ginsburg, S. B., Algohary, A., Pahwa, S., Gulani, V., Ponsky, L., Aronen, H. J., Boström, P. J., Böhm, M., Haynes, A., Brenner, P., Delprado, W., Thompson, J., Pulbrock, M., Taimen, P., Villani, R., Stricker, P., Rastinehad, A. R., Jambor, I., & Madabhushi, A.
Venue
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Published
2016-12-19
Volume
46
Issue
1
Pages
184-193
ISSN
  • 1053-1807 (ISSN-L)
  • 1522-2586
OpenAlex
W2562490391
Cited by
143
References
5
FWCI
11.83
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.