Automated image quality evaluation of T2‐weighted liver MRI utilizing deep learning architecture
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Purpose: To develop and test a deep learning approach named Convolutional Neural Network (CNN) for automated screening of T 2‐weighted (T 2 WI) liver acquisitions for nondiagnostic images, and compare this automated approach to evaluation by two radiologists. Materials and Methods: We evaluated 522 liver magnetic resonance imaging (MRI) exams performed at 1.5T and 3T at our institution between November 2014 and May 2016 for CNN training and validation. The CNN consisted of an input layer, convolutional layer, fully connected layer, and output layer. 351 T 2 WI were anonymized for training. Each case was annotated with a label of being diagnostic or nondiagnostic for detecting lesions and assessing liver morphology. Another independently collected 171 cases were sequestered for a blind test. These 171 T 2 WI were assessed independently by two radiologists and annotated as being diagnostic or nondiagnostic. These 171 T 2 WI were presented to the CNN algorithm and image quality (IQ) output of the algorithm was compared to that of two radiologists. Results: There was concordance in IQ label between Reader 1 and CNN in 79% of cases and between Reader 2 and CNN in 73%. The sensitivity and the specificity of the CNN algorithm in identifying nondiagnostic IQ was 67% and 81% with respect to Reader 1 and 47% and 80% with respect to Reader 2. The negative predictive value of the algorithm for identifying nondiagnostic IQ was 94% and 86% (relative to Readers 1 and 2). Conclusion: We demonstrate a CNN algorithm that yields a high negative predictive value when screening for nondiagnostic T 2 WI of the liver. Level of Evidence: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;47:723–728.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
Gradient-based learning applied to document recognition
Lecun, Y., Bottou, L., Bengio, Y., & Haffner, P. (1998) · Proceedings of the IEEE · doi:10.1109/5.726791 · Cited by 58,805
Machine learning and its applications to biology
Tarca, A. L., Carey, V. J., Chen, X.-W., Romero, R., & Drăghici, S. (2007) · PLoS Computational Biology · doi:10.1371/journal.pcbi.0030116 · Cited by 656 · cited 1×
“A confusion matrix is a commonly used method for evaluating machine-learning algorithms.(22) Analysis was performed using MedCalc v.”
Method
Cited by
Current Applications and Future Impact of Machine Learning in Radiology
Choy, G., Khalilzadeh, O., Michalski, M., Do, S., Samir, A. E., Pianykh, O. S., Geis, J. R., Pandharipande, P. V., Brink, J. A., & Dreyer, K. J. (2018) · Radiology · doi:10.1148/radiol.2018171820 · Cited by 800
Deep learning in medical imaging and radiation therapy
Sahiner, B., Pezeshk, A., Hadjiiski, L. M., Wang, X., Drukker, K., Cha, K. H., Summers, R. M., & Giger, M. L. (2019) · Medical Physics · doi:10.1002/mp.13264 · Cited by 740
Convolutional Neural Networks for Radiologic Images: A Radiologist’s Guide
Soffer, S., Ben-Cohen, A., Shimon, O., Amitai, M. M., Greenspan, H., & Klang, E. (2019) · Radiology · doi:10.1148/radiol.2018180547 · Cited by 577
Mazurowski, M. A., Buda, M., Saha, A., & Bashir, M. R. (2019) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26534 · Cited by 554
Artificial intelligence in medical imaging of the liver
Zhou, L.-Q., Wang, J.-Y., Yu, S.-Y., Wu, G.-G., Wei, Q., Deng, Y.-B., Wu, X.-L., Cui, X.-W., & Dietrich, C. F. (2019) · World Journal of Gastroenterology · doi:10.3748/wjg.v25.i6.672 · Cited by 262
Artificial intelligence in diagnostic imaging: impact on the radiography profession
Hardy, M., & Harvey, H. (2020) · The British Journal of Radiology · doi:10.1259/bjr.20190840 · Cited by 255
Artificial intelligence in emergency radiology: A review of applications and possibilities
Katzman, B. D., van der Pol, C. B., Soyer, P., & Patlas, M. N. (2023) · Diagnostic and Interventional Imaging · doi:10.1016/j.diii.2022.07.005 · Cited by 97
Reynés-Llompart, G., Sabaté-Llobera, A., Llinares-Tello, E., Martí-Climent, J. M., & Gámez-Cenzano, C. (2019) · Scientific Reports · doi:10.1038/s41598-019-46937-8 · Cited by 35
Uncertainty Quantification in Deep Learning for Safer Neuroimage Enhancement
Tanno, R., Worrall, D., Kaden, E., Ghosh, A., Grussu, F., Bizzi, A., Sotiropoulos, S. N., Criminisi, A., & Alexander, D. C. (2019) · arXiv · doi:10.48550/arxiv.1907.13418 · Cited by 30
Metadata
- Authors
- Esses, S. J., Lu, X., Zhao, T., Shanbhogue, K., Dane, B., Bruno, M., & Chandarana, H.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2017-06-03
- Volume
- 47
- Issue
- 3
- Pages
- 723-728
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2620818159
- Cited by
- 97
- References
- 3
- FWCI
- 4.63
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.